Pediatric supraglottic airway devices in clinical practice: A prospective observational study

نویسندگان

  • Maren Kleine-Brueggeney
  • Anne Gottfried
  • Sabine Nabecker
  • Robert Greif
  • Malte Book
  • Lorenz Theiler
چکیده

BACKGROUND Supraglottic airway devices (SGA) are commonly used in pediatric anesthesia and serve as primary or back-up devices for difficult airway management. Most SGA are marketed without proper clinical evaluation. The purpose of this study was to evaluate the performance of the pediatric LMA Supreme™, Air-Q® and Ambu® Aura-i™. METHODS This prospective observational study was performed at Bern University Hospital, Switzerland. With ethics committee approval and a waiver for written informed consent 240 children undergoing elective surgery with an ASA class I-III and a weight of 5-30 kg were included. Three different pediatric supraglottic airway devices were assessed: The LMA Supreme™, Air-Q® and Ambu® Aura-i™. Primary outcome parameter was airway leak pressure. Secondary outcome parameters included first attempt and overall success rate, insertion time, fiberoptic view through the SGA, and adverse events. The primary hypothesis was that the mean airway leak pressure of each tested SGA was 20 cmH2O ± 10%. RESULTS None of the SGA showed a mean airway leak pressure of 20 cmH2O ± 10%, but mean airway leak pressures differed significantly between devices [LMA Supreme™ 18.0 (3.4) cmH2O, Air-Q® 15.9 (3.2) cmH2O, Ambu® Aura-i™ 17.3 (3.7) cmH2O, p < 0.001]. First attempt success rates (LMA Supreme™ 100%, Air-Q® 90%, Ambu® Aura-i™ 91%, p = 0.02) and overall success rates (LMA Supreme™ 100%, Air-Q® 91%, Ambu® Aura-i™ 95%, p = 0.02) also differed significantly. Insertion times ranged from 20 (7) seconds (Air-Q®) to 24 (6) seconds (LMA Supreme™, <p = 0.005). Insertion was rated easiest with the LMA Supreme™ (very easy in 97% vs. Air-Q® 70%, Ambu® Aura-i™ 72%, p < 0.001). Fiberoptic view was similar between the SGA. Adverse events were rare. CONCLUSIONS Airway leak pressures ranged from 16 to 18 cmH2O, enabling positive pressure ventilation with all successful SGA. The highest success rates were achieved by the LMA Supreme™, which was also rated easiest to insert. TRIALS REGISTRATION ClinicalTrials.gov , identifier NCT01625858 . Registered 31 May 2012.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative evaluation of LMA-Supreme and i-gel supraglottic airway devices with endotracheal intubation during surgical correction of traumatic orbital injuries

Aims. The aim of the study was to compare endotracheal intubation with i-gel and LMA (laryngeal mask airway) supreme supraglottic airway devices in orbital osteosynthesis surgery. Methods. 134 patients undergoing orbital plasty after fracture were enrolled in our study and were randomized into three groups: 43 in the endotracheal intubation group, 42 in the LMA-Supreme group, and 49 patients w...

متن کامل

Comparative Efficacy of the Air-Q Intubating Laryngeal Airway during General Anesthesia in Pediatric Patients: A Systematic Review and Meta-Analysis

Air-Q® (air-Q) is a supraglottic airway device which can be used as a guidance of intubation in pediatric as well as in adult patients. We evaluated the efficacy and safety of air-Q compared to other airway devices during general anesthesia in pediatric patients by conducting a systematic review and meta-analysis. A total of 10 studies including 789 patients were included in the final analysis....

متن کامل

An update on newer pediatric supraglottic airways with recommendations for clinical use.

Supraglottic airways are an established part of routine and emergency pediatric airway management, including use in difficult airways and neonatal resuscitation. With the introduction of newer supraglottic airways in children, efficacy can only be determined by comparing these devices with those that are already well established (laryngeal mask airway Classic and laryngeal mask airway ProSeal)....

متن کامل

Complications with supraglottic airways: something to worry about or much ado about nothing?

T HE supraglottic airways have gained firm places in anesthetic practice since clinical introduction of the laryngeal mask airway (LMA) Classic (LMA North America, Inc., San Diego, CA) in 1988. Although they are generally being used safely, serious complications occasionally do occur during the use of the airways. To increase safety, we need to know the types, severity, and possible causative f...

متن کامل

Comparison of blind intubation through supraglottic devices and direct laryngoscopy by novices: a simulation manikin study

OBJECTIVE This study aimed to compare intubation performance between blind intubation through supraglottic airway devices and direct laryngoscopy by novices under manikin simulation. We hypothesized that the intubation time by novices using supraglottic airway devices was superior to that with the Macintosh laryngoscope (MCL). METHODS A prospective, randomized crossover study was conducted wi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017