Comparison of planning techniques when air/fluid is present using the strut‐adjusted volume implant (SAVI) for HDR‐based accelerated partial breast irradiation
نویسندگان
چکیده
The presence of air/fluid surrounding implantable devices used for partial breast irradiation may significantly impact dose coverage to at-risk tissue. Of the 67 total patients retrospectively evaluated for this study, 32 (48%) had greater than 1 cc volume of air/fluid extending outside of the strut-adjusted volume implant (SAVI) device surface and were selected for comparison of planning approaches. The planning approaches utilized two different definitions of PTV_EVAL. One definition of a PTV_EVAL (PTV_EVALSAVI) was based on expanding 1 cm beyond the SAVI device only while accounting for the air/fluid using the NSABP Protocol B-39/RTOG Protocol 0413. The second PTV_EVAL definition (PTV_EVALCAV) was based on expanding 1 cm beyond the cavity (SAVI device plus air/fluid volume). The results indicate use of the B-39 formalism to account for air/fluid displacing the PTV_EVAL may overestimate the dose coverage to the at-risk tissue, especially for large contiguous volumes of air/fluid. Using the SAVI device to optimize dose covering the PTV_EVALCAV volume surrounding the cavity improves dosimetric coverage to at-risk tissue by 11.3% and 8.7% for V100 and V90, respectively, while the average V150 and V200 indices for PTV_EVALCAV increased by 9.1 cc and 5.0cc, respectively, and the average maximum rib and skin doses increased by 11.1% and 6.1%, respectively. The maximum skin dose, rib dose, V150, and V200 all met the planning objectives despite any increase in these parameters.
منابع مشابه
A study on dosimetry accuracy of Strut-Adjust Volume Implant (SAVI) brachytherapy
Introduction: Accelerated Partial Breast Irradiation (APBI) is an effective treatment for breast carcinomas because of its limited number of fractions. Strut-adjusted volume implant (SAVI) is a HDR brachytherapy applicator to deliver the prescription dose with good PTV coverage and acceptable dose to skin, chest wall and organ at risks. Acceptable clinical outcomes depend on a...
متن کاملClinical implementation of a new HDR brachytherapy device for partial breast irradiation.
PURPOSE To present the clinical implementation of a new HDR device for partial breast irradiation, the Strut-Adjusted Volume Implant (SAVI), at the University of California, San Diego. METHODS AND MATERIALS The SAVI device has multiple peripheral struts that can be differentially loaded with the HDR source. Planning criteria used for evaluation of the treatment plans included the following do...
متن کاملDosimetrical Evaluation and Clinical Implementation of a Strut-adjusted-volume-implant Savi Device Used for Accelerated Partial Breast Irradiation
The SAVI (the Strut Adjusted Volume Implant) device is one of the most novel devices used in Accelerated Partial Breast Irradiation (APBI). Various dosimetric parameters, as well as doses to adjacent critical structures, have been evaluated in 121 patients in this single institution 5-year retrospective study, using dose volume histogram (DVHs): Coverage Index (CI), cavity and planning target v...
متن کاملDosimetric performance of Strut-Adjusted Volume Implant: a new single-entry multicatheter breast brachytherapy applicator.
PURPOSE To evaluate the dosimetric performance and clinical utility of the Strut-Adjusted Volume Implant (SAVI) (Cianna Medical, Aliso Viejo, CA) applicator when used as the sole method of radiation therapy for patients with early breast carcinoma. METHODS AND MATERIALS The dosimetric performance of a Phase II clinical trial has been reported using the SAVI applicator for patients with early ...
متن کاملAccelerated partial breast irradiation using the strut-adjusted volume implant single-entry hybrid catheter in brachytherapy for breast cancer in the setting of breast augmentation.
PURPOSE Accelerated partial breast irradiation (APBI) has gained popularity as an alternative to adjuvant whole breast irradiation; however, owing to limitations of delivery devices for brachytherapy, APBI has not been a suitable option for all the patients. This report evaluates APBI using the strut-adjusted volume implant (SAVI) single-entry catheter to deliver brachytherapy for breast cancer...
متن کامل