The effect of variations of pulsed Doppler sampling site on calculation of cardiac output: an experimental study in open-chest dogs.

نویسندگان

  • D C Fisher
  • D J Sahn
  • M J Friedman
  • D Larson
  • L M Valdes-Cruz
  • S Horowitz
  • S J Goldberg
  • H D Allen
چکیده

We measured aortic flow by two-dimensional Doppler echocardiography in an open-chest dog model to examine how variations in Doppler sample volume length and position influence aortic hemodynamic flow calculations. Fourteen dogs underwent right-heart bypass, in which venous return from the venae cavae drained by gravity to a reservoir. A variable-speed roller pump returned the blood to the pulmonary artery, fixing left-sided cardiac input and output. Echo Doppler measurements were performed using a 3.5 MHz transducer placed directly on the aortic arch to determine internal aortic cross-sectional area. The transducer was then directed to image the aortic arch for Doppler velocity measurements and the various sampling sites were investigated. Doppler cardiac output could then be determined for each of the various sample volumes over a range of known roller pump settings. Doppler velocity was analyzed using fast Fourier transform spectral analysis. Mean velocity over the cardiac cycle was obtained by planimetry of the area under the Doppler velocity curve with a minicomputer. Doppler-derived determinations of cardiac output achieved a correlation of r = 0.98-0.99 to values obtained by the roller pump over a range of cardiac outputs from 0.75-5 l/min. The standard error of the estimate was 0.21/min. In this laminar flow model, there was no difference between the predictive accuracy of any of the sampling sites over the range of roller pump flows. Our study shows that Doppler velocity measurements can be used to quantify aortic flow over a clinically useful range and that variations of sample length and position did not produce significant differences in calculated flows.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Normal Color and Pulsed-Waved Doppler Ultrasonography of Femoral and Axillary Arteries in Dogs

Objective- Obtaining the normal images ofcolor doppler and estimation ofblood flow velocity parametersof femoral and axillary arteries in dog.Design- Descriptive studyAnimals- 7 healthy adult mixed-breed dogs, weighing 14.3 ± 2.8 kg (mean ± SD).Proceudure- Left and right femoral and axillary arteries of hind and forelimbs were evaluated. Colorand spectral doppler images ofthe each artery were o...

متن کامل

Echocardiographic Measurement of Systolic Time Intervals in Healthy Great Dane Dogs

Objective- to determine the range of systolic times intervals using Pulsed-wave Doppler and m-mode echocardiography in normal, healthy Great Dane dogs. Design- Descriptive study. Animals- Thirty healthy Great Dane dogs. Procedures- This study examined 30 clinically healthy Great Dane dogs by the twodimensional, M-mode and Pulsed-wave Doppler echocardiography. The dogs were awake and unsedated. ...

متن کامل

Normal pulsed wave Doppler echocardiographic parameters of Turkmen horses of Iran

Turkmen horse is one of the oldest and purest breeds in the world, but there is no information on Doppler echocardiographic parameters in this horse. In the present study, pulsed-wave (PW) Doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing Turkmen horses. No cardiac disease was detected with two-dimensional (2-D) real-time, M-mode, and colour flow mapping. D...

متن کامل

Study of Cardiac Parameters by Pulsed Wave Doppler Echocardiography in Normal Healthy Markhoz Goat

Objective- The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy Markhoz goats.Design- Retrospective study.Animals- 20 female Markhoz goats.Procedure- Using a standardized PW Doppler echocardiographic protocol, 20healthy adult unsedated female Markhoz goats were investigated three times at one-...

متن کامل

تأثیر طب فشاری بر شدت درد ناشی از خارج-کردن لوله درناژ قفسه صدری در بیماران تحت جراحی قلب باز در بخش مراقبت‌های ویژه

 Background and Objective: Pain due to chest tube removal (CTR) is a major complaint among patients who undergo open heart surgery. This study was carried out to investigate the effect of acupressure on pain intensity after chest tube removal in patients with open heart surgery in intensive care unit (ICU).   Materials and Methods: This research study was a randomized controlled clinical tr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 67 2  شماره 

صفحات  -

تاریخ انتشار 1983