Detecting Breaths in Capnography Time Series

نویسندگان

  • Markus Nilsson
  • Mattias Karlsson
  • Andreas Selenwall
  • Peter Funk
چکیده

Finding individual breaths is essential in the classification of respiratory sinus arrhythmia. The identification task may become quite difficult if the sampling rates of available physiological measurements are low, as in the HR3Modul decision support system. We introduce an improved respiration analysis of the HR3Modul system that uses an Euclidian distance based Nearest-Neighbour classification of low resolution capnography time-series in order to detect individual breaths. The classification uses an additional case library that is independent from the already existing one (in HR3Modul) in the identification process.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Description of an assembled noninvasive capnography setup.

BACKGROUND Noninvasive capnography is not routinely available on portable transport patient monitors but can be useful in respiratory monitoring of spontaneously breathing patients during transport, especially when sedation is administered. We describe an assembled setup of face mask capnography. The purpose of this study was to assess the feasibility and performance of an assembled face mask c...

متن کامل

Multicenter Study Validating Accuracy of a Continuous Respiratory Rate Measurement Derived From Pulse Oximetry: A Comparison With Capnography

BACKGROUND Intermittent measurement of respiratory rate via observation is routine in many patient care settings. This approach has several inherent limitations that diminish the clinical utility of these measurements because it is intermittent, susceptible to human error, and requires clinical resources. As an alternative, a software application that derives continuous respiratory rate measure...

متن کامل

Capnography monitoring enhances safety of postoperative patient-controlled analgesia.

BACKGROUND Patient-controlled analgesia is associated with potentially fatal opioid-related respiratory depression. Opioids are a well-recognized cause of respiratory depression. However, in the postoperative patient, unrecognized pulmonary disease may lead to retention of carbon dioxide, which is further antagonized by opioids and may lead to life-threatening respiratory depression. Therefore,...

متن کامل

The accuracy of non-invasive nasal capnography in morbidly obese patients after bariatric surgery.

STUDY OBJECTIVE to assess the accuracy of nasal capnography for the monitoring of ventilation in extubated morbidly obese patients, following bariatric surgery. DESIGN prospective descriptive study. SETTING Post-anesthesia care unit. PATIENTS 25 consecutive morbidly obese patients admitted to the PACU after open bariatric surgery. INTERVENTION Patients had a nasal cannula designed to ad...

متن کامل

Accuracy of acoustic respiration rate monitoring in pediatric patients.

BACKGROUND Rainbow acoustic monitoring (RRa) utilizes acoustic technology to continuously and noninvasively determine respiratory rate from an adhesive sensor located on the neck. OBJECTIVE We sought to validate the accuracy of RRa, by comparing it to capnography, impedance pneumography, and to a reference method of counting breaths in postsurgical children. METHODS Continuous respiration r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005