Haemodynamic response at double lumen bronchial tube placement - Airtraq vs. MacIntosh laryngoscope, a randomised controlled trial
نویسندگان
چکیده
INTRODUCTION Tracheal intubation causes a haemodynamic response that might be harmful for patients. The Airtraq® laryngoscope has been shown to decrease the haemodynamic response to single-lumen tube intubation. We hypothesised that double-lumen bronchial tube placement with the Double-lumen Airtraq® laryngoscope would cause a reduced haemodynamic response and decreased catecholamine release compared with the MacIntosh laryngoscope. METHODS Forty adult patients were randomly assigned to the Airtraq® group or to the MacIntosh group. Intubation with either the Airtraq® or the MacIntosh laryngoscope was performed two minutes after standardised induction of anaesthesia. Arterial blood pressure, heart rate, catecholamine levels, bispectral index and duration of the intubation procedure were measured. RESULTS Mean (standard deviation [95% confidence interval]) systolic arterial blood pressure at laryngoscopy with the Airtraq® laryngoscope was 124 (34 [106 to 141]) mmHg and, with the MacIntosh laryngoscope, it was 110 (25 [99 to 122]) mmHg (p=1.0). Heart rate at laryngoscopy with the Airtraq® laryngoscope was 75 beats·min-1 (16 [67 to 83]) and, with the MacIntosh laryngoscope, it was 64 beats·min-1 (14 [58 to 71]) (p=0.71). Adrenaline levels post-intubation were 54.3 ng·l-1 (41.5) [29.3 to 79.4] in the Airtraq® group and 30.5 ng·l-1 (25.6) [15.1 to 46.0] in the MacIntosh group (p=0.016). The duration of intubation with the Airtraq® laryngoscope was 88 s (31 [72-104]) while, with the MacIntosh laryngoscope, the duration was 75 s (35 [59-92]) (p=0.26). CONCLUSIONS The use of the Double-lumen Airtraq® laryngoscope provides no benefit regarding stress response compared to the MacIntosh laryngoscope.
منابع مشابه
Comparison of the Airtraq laryngoscope and the GlideScope for double-lumen tube intubation in patients with predicted normal airways: a prospective randomized trial
BACKGROUND The Airtraq laryngoscope and the GlideScope are commonly used in many airway scenarios. However, their features have not been fully described for double-lumen tube intubation. A prospective randomized study was designed to compare their intubation performances in thoracic surgery patients. METHODS Seventy ASA physical status I and II patients with predicted normal airway were sched...
متن کاملA comparison of tracheal intubation using the Airtraq or the Macintosh laryngoscope in routine airway management: A randomised, controlled clinical trial.
The Airtraq laryngoscope is a novel single use tracheal intubation device. We compared the Airtraq with the Macintosh laryngoscope in patients deemed at low risk for difficult intubation in a randomised, controlled clinical trial. Sixty consenting patients presenting for surgery requiring tracheal intubation were randomly allocated to undergo intubation using a Macintosh (n = 30) or Airtraq (n ...
متن کاملAirway management at floor level: a comparison of tracheal intubation using the Macintosh and Airtraq laryngoscopes.
Practitioners providing pre-hospital care during civilian practice and on military operations may be required to perform airway management and tracheal intubation at floor level. It has been shown that intubation using the Airtraq laryngoscope is easier to learn than standard Macintosh laryngoscopy. We hypothesised that the Airtraq would be easier to use and have shorter intubation times than M...
متن کاملA randomised crossover trial comparing the Airtraq(®) NT, McGrath(®) MAC and Macintosh laryngoscopes for nasotracheal intubation of simulated easy and difficult airways in a manikin.
OBJECTIVE Several devices can aid nasotracheal intubation when managing difficult airways. The McGrath MAC and Airtraq NT were compared with a Macintosh laryngoscope when studying the performance of anaesthetists with different levels of experience, in a manikin model of easy or difficult airway scenarios. METHODS Sixty-three anaesthetists were recruited into a randomised trial in which each ...
متن کاملMcGrath Series 5 videolaryngoscope vs Airtraq DL videolaryngoscope for double-lumen tube intubation
BACKGROUND Many studies have shown Airtraq videolaryngoscope provided faster tracheal intubation and a higher success rate than other videolaryngoscopes. Recently, different types of videolaryngoscopes have been reported for use in double-lumen tube (DLT) intubation. However, the advantages and disadvantages between them remain undetermined for DLT intubation. In this study, we compared the Air...
متن کامل