Wide-Dynamic-Range “Neutron Bang Time” Detector on OMEGA
ثبت نشده
چکیده
LLE Review, Volume 88 17
منابع مشابه
بهینهسازی پاسخ دزیمتری نوترون در بازه انرژی حرارتی و سریع برای آشکارساز دیودی
During the last few years, real time gamma and neutron dosimeters have been developed and semiconductor diodes are frequently used in these dosimeters. Semiconductor diodes are used to charged particle detection. For sensitizing the detector to neutrons, a converter layer is contacted on the front surfaces of them. Incident neutrons interact with the converter and produce charged particles that...
متن کاملNeutron Detection with High Bandwidth and High Dynamic Range
A neutron diagnostic for inertial confinement fusion (ICF) experiments was designed and fabricated that is suitable for both the OMEGA and National Ignition Facility (NIF) laser systems. The diagnostic measures the spectrum of fusion neutrons that are generated at peak compression. The neutrons are downshifted, or lose energy, as they escape depending on the areal density (ρr) of the imploded t...
متن کاملA method for in situ absolute DD yield calibration of neutron time-of-flight detectors on OMEGA using CR-39-based proton detectors.
Neutron time of flight (nTOF) detectors are used routinely to measure the absolute DD neutron yield at OMEGA. To check the DD yield calibration of these detectors, originally calibrated using indium activation systems, which in turn were cross-calibrated to NOVA nTOF detectors in the early 1990s, a direct in situ calibration method using CR-39 range filter proton detectors has been successfully...
متن کاملSensitivity of chemical vapor deposition diamonds to DD and DT neutrons at OMEGA and the National Ignition Facility.
The particle-time-of-flight (pTOF) detector at the National Ignition Facility (NIF) is used routinely to measure nuclear bang-times in inertial confinement fusion implosions. The active detector medium in pTOF is a chemical vapor deposition diamond. Calibration of the detectors sensitivity to neutrons and protons would allow measurement of nuclear bang times and hot spot areal density (ρR) on a...
متن کاملPrototypes of NIF Neutron Time-of-Flight Detectors Tested on OMEGA
Every large ICF laser facility, including Nova, OMEGA, and GEKKO, uses neutron time-of-flight (nTOF) systems to measure neutron yields and ion temperatures. Such nTOF systems are usually based on current-mode detectors consisting of a fast plastic scintillator optically coupled to a fast photomultiplier tube (PMT). A high-bandwidth transient digitizer records the signal. These systems, which ar...
متن کامل