Antibody-based immobilization of bioluminescent bacterial sensor cells.
نویسندگان
چکیده
Whole-cell luminescent bioreporter sensors based on immobilized recombinant Escherichia coli are described and evaluated. The sensors were prepared by glutaraldehyde-anchoring of nonspecific anti-E. coli antibodies on aminosylilated gold or silica glass surfaces with subsequent attachment of the probe bacteria. We demonstrate the generality of the concept by attachment of several E. coli strains that express luciferase in response to different physiological stress conditions including heat shock, DNA damage (SOS), fatty acid availability, peroxide and oxidative stress. The sensors can be used either as single- or multiple-use disposable sensing elements or for continuous operation. We show compatibility with optical fiber technology. Storage stability of the sensors exceeded 5 months with no measurable deterioration of the signal. Repeatability on exposure in successive days was <15%, as was sensor to sensor reproducibility. Sensitivity and detection limits of the immobilized cells were comparable to that of non-immobilized bacteria.
منابع مشابه
Nanobiosensor designing with molecular framework polymer method compared with agent-linked nanosilica biosensor for Staphylococcus aureus exotoxin detection
Considering the ever increasing population and industrialization leading to developmental trend of humankind's life, we are hardly able to detect the toxins produced in food products using traditional techniques. In this technique, the production of molecular framework and polymer is done using meta acrylic acid monomers, which are formed via covalence connection between meta acrylic acid monom...
متن کاملNanobiosensor designing with molecular framework polymer method compared with agent-linked nanosilica biosensor for Staphylococcus aureus exotoxin detection
Considering the ever increasing population and industrialization leading to developmental trend of humankind's life, we are hardly able to detect the toxins produced in food products using traditional techniques. In this technique, the production of molecular framework and polymer is done using meta acrylic acid monomers, which are formed via covalence connection between meta acrylic acid monom...
متن کاملDesign novel optical sensor for determination of bismuth based on immobilization of 4-(4-nitrophenyl)-1-naphthol on a triacetylcellulose membrane
A novel optical sensor has been proposed for sensitive determination of bismuth ion basedon immobilization of 4-(4-nitrophenylazo)-1-naphthol on a triacetylcellulose membrane.Chemical binding of bismuth ions in solution with a 4-(4-nitrophenylazo)-1-naphtholimmobilized on the triacetylcelluse surface could be monitored spectrophotometrically. Theoptode shows excellent response over wide concent...
متن کاملBioluminescent Antibodies for Point‐of‐Care Diagnostics
We introduce a general method to transform antibodies into ratiometric, bioluminescent sensor proteins for the no-wash quantification of analytes. Our approach is based on the genetic fusion of antibody fragments to NanoLuc luciferase and SNAP-tag, the latter being labeled with a synthetic fluorescent competitor of the antigen. Binding of the antigen, here synthetic drugs, by the sensor displac...
متن کاملThe Repetitive Detection of Toluene with Bioluminescence Bioreporter Pseudomonas putida TVA8 Encapsulated in Silica Hydrogel on an Optical Fiber
Living cells of the lux-based bioluminescent bioreporter Pseudomonas putida TVA8 were encapsulated in a silica hydrogel attached to the distal wider end of a tapered quartz fiber. Bioluminescence of immobilized cells was induced with toluene at high (26.5 mg/L) and low (5.3 mg/L) concentrations. Initial bioluminescence maxima were achieved after >12 h. One week after immobilization, a biofilm-l...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Talanta
دوره 55 5 شماره
صفحات -
تاریخ انتشار 2001