Accuracy of a Pedometer and an Accelerometer in Women with Obesity
نویسندگان
چکیده
Aim: The main purpose of this study was to examine the accuracy of a specific pedometer (Silva model Pedometer Plus 56013-3) and accelerometer (Silva model Ex3 plus 56026) in women suffering from obesity. The second aim was to study the impact of BMI, waist and hip circumference and waist-hip ratio on different pedometer and accelerometer positions on the body. Methods: Forty women with a BMI > 30 kg/m wore two pedometers and two accelerometers during a standardized 6 minute walk test. Accelerometer 1 (A1) was placed around the neck. Accelerometer 2 (A2) was attached to the waistband of the woman’s trousers in line with left hip, Pedometer 1 (P1) in line with right hip and pedometer 2 (P2) behind back in line with the spine. During the test an assistant manually counted number of steps, using a hand counter as reference for step accuracy. Results: Steps registered with the pedometer were significantly different from actual steps counted. The intra class correlations for the actual steps counted compared with the steps registered were P1 = 0.13, P2 = 0.20, A1= 0.99 and A2 = 0.41. All correlations between the tested pedometer and accelerometer at the different locations and BMI, waist circumference, hip circumference and hip-to waist ratio were little (if any) or low. Conclusions: The accelerometer is more accurate than the pedometer in measuring steps in women suffering from obesity. The location, which gave the most accurate results, was found to be around the neck.
منابع مشابه
Agreement between pedometer and accelerometer in measuring physical activity in overweight and obese pregnant women
BACKGROUND Inexpensive, reliable objective methods are needed to measure physical activity (PA) in large scale trials. This study compared the number of pedometer step counts with accelerometer data in pregnant women in free-living conditions to assess agreement between these measures. METHODS Pregnant women (n = 58) with body mass index ≥25 kg/m(2) at median 13 weeks' gestation wore a GT1M A...
متن کاملMeasuring physical activity during pregnancy
BACKGROUND Currently, little is known about physical activity patterns in pregnancy with prior estimates predominantly based on subjective assessment measures that are prone to error. Given the increasing obesity rates and the importance of physical activity in pregnancy, we evaluated the relationship and agreement between subjective and objective physical activity assessment tools to inform re...
متن کاملAccuracy of piezoelectric pedometer and accelerometer step counts.
BACKGROUND This study aimed to assess step-count accuracy of a piezoeletric pedometer (Yamax PW/EX-510), when worn at different body parts, and a triaxial accelerometer (GT3X+), and to compare device accuracy; and identify the preferred location(s) to wear a pedometer. METHODS Sixty-three healthy adults (45.8±20.6 years old) wore 7 pedometers (neck, lateral right and left of the waist, front ...
متن کاملAccuracy of Neck Circumference as a Screening Tool in Classifying General and Central Obesity
Objective: the neck circumference (NC) as an index of obesity and upper-body subcutaneous adipose tissue distribution is recently used. This alternative screening tool is reliable, simple, quick and acceptable for assessment of overweight and obesity. the objectives of this study were to examine the correlation between NC measurement and diagnosis of general/visceral obesity and determining the...
متن کاملHow many days of monitoring predict physical activity and sedentary behaviour in older adults?
BACKGROUND The number of days of pedometer or accelerometer data needed to reliably assess physical activity (PA) is important for research that examines the relationship with health. While this important research has been completed in young to middle-aged adults, data is lacking in older adults. Further, data determining the number of days of self-reports PA data is also void. The purpose of t...
متن کامل