PTOSL response of commercial Al2O3:C detectors to ultraviolet radiation.

نویسندگان

  • Claudia C Gronchi
  • Linda V E Caldas
چکیده

The photo-transferred optically stimulated luminescence (PTOSL) technique using Al2O3:C detectors has been suggested as a good option for ultraviolet (UV) radiation dosimetry. The objective of this work was to study the PTOSL response of Al2O3:C InLight detectors and the OSL microStar reader of Landauer. The parameters such as radiation pre-dose, optical treatment time and UV illumination time were determined. The detectors presented a satisfactory stimulus of PTOSL signals when they were subjected to a preconditioning procedure with gamma radiation (1 Gy pre-dose), 30 min of optical treatment (to empty the shallow traps) and 30 min of UV illumination from an artificial source.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiotherapy dosimetry using a commercial OSL system.

A commercial optically stimulated luminescence (OSL) system developed for radiation protection dosimetry by Landauer, Inc., the InLight microStar reader, was tested for dosimetry procedures in radiotherapy. The system uses carbon-doped aluminum oxide, Al2O3:C, as a radiation detector material. Using this OSL system, a percent depth dose curve for 60Co gamma radiation was measured in solid water...

متن کامل

Experimental and Monte Carlo studies on the response of CR-39 detectors to Am-Be neutron spectrum

Background: The Poly-Allyl Diglycol Carbonate (PADC) detector is of particular interest for development of a fast neutron dosimeter. Fast neutrons interact with the constituents of the CR-39 detector and produce H, C and O recoils, as well as (n, α) reaction. These neutron- induced charged particles contribute towards the response of CR-39 detectors. Material and Methods: Electrochemical...

متن کامل

The Effect of Short-Range Radiation of Type C and B Ultraviolet on the Mechanical Properties of Skin Fibroblasts

The effect of UV beam, which has been emitted from a natural or a manmade source on cells has been studied in previous studies for several times. Radiation of this beam can have different effects on DNA of the cell, cytotoxicity, the structure of cellular proteins and their mechanical properties based on radiation period or frequency. The effect of radiation of two types of beams, namely UVB an...

متن کامل

Ultraviolet detectors based on annealed zinc oxide thin films: epitaxial growth and physical characterizations

In this report, ultraviolet (UV) detectors were fabricated based on zinc oxide thin films. The epitaxial growth of zinc oxide thin films was carried out on bare glass substrate with preferred orientation to (002) plane of wurtzite structure through radio frequency sputtering technique. The structural properties indicated a dominant peak at 2θ=34.28º which was matched with JCPDS reference card N...

متن کامل

Response of conifers to UV-B and climate in mountain areas

The present study was focused to examine the combined effects of climate and ultraviolet-B radiation on conifer tree-ring density. Statistical methods were employed to extract tree responses in annual ring density and to identify functional relationship in trees when the level of ultraviolet-B radiation changes regardless of climate variations. In this study, the consideration was given to the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 154 1  شماره 

صفحات  -

تاریخ انتشار 2013