The Release of Elements from Dental Casting Alloy into Cell-Culture Medium and Artificial Saliva
نویسندگان
چکیده
OBJECTIVES The biocompatibility of dental casting alloys is a critical issue because these alloys are in long-term intimate contact with oral tissues. Since the biocompatibility of alloys is not completely known; the release of elements from the alloys has been studied. The aim of this study was to compare the elemental release from dental casting alloy during exposure to artificial saliva and cell-culture medium. MATERIALS AND METHODS Twenty specimens made from Ni-Cr alloy were provided in the form of 5 mm diameter discs, 2 mm in thickness with a 7 mm stem attached to one face to facilitate handling. Ten of twenty samples were polished separately using a conventional technique. The remaining ten samples were left sandblasted with 50 mum Al(2)0(3). Ten samples (5 polished, 5 sandblasted) were separately placed into cell-culture wells with Dulbecco's Modified Eagle's Medium. The other ten samples were placed separately into cell-culture wells with artificial saliva. The samples were subjected in contact with these medium for 30 days. These medium were collected every 7 days. The cell-culture medium and artificial saliva without alloy samples were subjected to elemental analyses as a control. At the end of the exposure time, Atomic Absorption Spectrometry (AAS) was used to determine the release of elements from the alloys into all collected medium. Statistical analyses were assessed with two-way ANOVA. RESULTS In general, the elemental release occurred with in all medium. The elemental releases of sandblasted alloys were higher than polished alloys. Artificial saliva was found to cause more release from the samples. In both media, Ni released from polished and sandblasted alloys were higher than Cr and Mo. CONCLUSIONS The results suggest that the release of elements from the alloys might have correlated with the environments and the surface of dental alloy.
منابع مشابه
The release of elements of dental casting alloys into cell-culture medium.
Ten dental casting alloys were tested for alloy-element release into cell-culture medium, and this release was related to alloy composition, alloy microstructure, and alloy cytotoxicity (previously determined). Cell-culture medium was analyzed for alloy elements by flame atomic absorption. Concentrations of elements in the medium were normalized by dividing them by their atomic abundance in the...
متن کاملA Comparative Analysis of the Corrosive Effect of Artificial Saliva of Variable pH on DMLS and Cast Co-Cr-Mo Dental Alloy
Dental alloys for direct metal laser sintering (DMLS) are available on the market today, but there is little scientific evidence reported on their characteristics. One of them is the release of ions, as an indicator of the corrosion characteristics of a dental alloy. Within this research, the difference in the elution of metals from DMLS and cast (CM) samples of Co-Cr-Mo dental alloy in saliva-...
متن کاملIon release from dental casting alloys as assessed by a continuous flow system: Nutritional and toxicological implications.
OBJECTIVES The aims of this study were to quantify the metallic ions released by various dental alloys subjected to a continuous flow of saliva and to estimate the nutritional and toxicological implications of such a release. METHODS Four pieces of three nickel-based, one noble, one high-noble and two copper-aluminum alloys were cast and then immersed in a continuous flow of artificial saliva...
متن کاملGalvanic Corrosion and Ion Release from Different Orthodontic Brackets and Wires in Acidic Artificial Saliva: Part I
Objective: Corrosion resistance is among the most important properties of metal alloys used in the oral cavity. Consumption of acidic foods reduces the salivary pH and intensifies the corrosion of brackets and orthodontic wires. This study aimed to compare electro galvanic corrosion of different orthodontic brackets and wires and determine the amount of ions released into acidic artifici...
متن کاملThiol modified Au nanoparticles grafted manganese doped magnetic iron oxide nanoparticles for spectrometric determination of short-term release of mercury and copper from dental amalgam in saliva
Abstract A new adsorbent, ethylene glycol bisthioglycolate modified gold nanoparticles grafted Mn doped Fe3O4 nanoparticles (EGBTG-Au@Mn-Fe3O4 NPs) were synthesized through chemical precipitation followed by an oxidative Mn doping process to use for extraction and preconcentration of trace amounts of Hg, and Cu ions in artificial and natural saliva. The prepared adsorbent was characterize...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European Journal of Dentistry
دوره 1 شماره
صفحات -
تاریخ انتشار 2007