Application of bioelectrical impedance to clinical assessment of body composition in peritoneal dialysis.

نویسندگان

  • Graham Woodrow
  • Yvette Devine
  • Mary Cullen
  • Elizabeth Lindley
چکیده

Patients on peritoneal dialysis (PD) develop complex changes in body composition. These changes reflect hydration, nutrition, and body fat, all important elements reflecting patient well-being and efficacy of therapy that should be assessed and monitored as guides to patient management. They are all notoriously difficult to accurately measure in clinical practice and simultaneous abnormalities may obscure detection, as in the malnourished fluid-overloaded patient where body weight is misleadingly stable. Malnutrition is a serious complication in PD that carries an adverse prognosis. Assessment of hydration in PD is important in determining "dry weight" to allow adjustment of dialysis prescription to optimize fluid balance. A number of techniques have been investigated to measure body composition in clinical practice. Of these, bioelectrical impedance analysis (BIA) has attracted most interest and seems to be of greatest promise. Cases illustrating different aspects of the use of BIA in PD patients are described, and the background, possible uses, and limitations of BIA in PD patients are discussed. To be of clinical value, BIA must be used to distinguish between extracellular water (which reflects hydration) and body cell mass, or intracellular water (which declines in wasting and malnutrition). The high precision of BIA is ideally suited to detecting changes in body composition and its main role may be in longitudinal monitoring. However, inaccuracy of absolute measurements and variability of normal values in the general population make precise diagnosis of the degree of normality of body composition in an individual subject a more difficult task for body composition analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bioelectrical Impedance versus Body Mass Index for Predicting Body Composition Parameters in Sedentary Job Women

Objective: Nowadays the value of bioelectrical impedance analysis (BIA) in the estimation of body adiposity both on a clinical basis in the individual and epidemiologically in large populations is of great interest. The current study determine accuracy of BIA compared with body mass index (BMI) measurement for estimating body composition in a group of normal weight employee women with a sedenta...

متن کامل

Does bioimpedance analysis or measurement of natriuretic peptides aid volume assessment in peritoneal dialysis patients?

Cardiovascular mortality remains the commonest cause of death for peritoneal dialysis patients. As such, preventing persistent hypervolemia is important. On the other hand, hypovolemia may potentially risk episodes of acute kidney injury and loss of residual renal function, a major determinant of peritoneal dialysis technique survival. Bioimpedance has developed from a single-frequency research...

متن کامل

ORIGINAL COMMUNICATION Accuracy of eight-polar bioelectrical impedance analysis for the assessment of total and appendicular body composition in peritoneal dialysis patients

Objective: To establish the accuracy of bioelectrical impedance analysis (BIA) for the assessment of total and appendicular body composition in peritoneal dialysis (PD) patients. Design: Cross-sectional study. Setting: University Nephrology Clinic. Subjects: In all, 20 PD patients and 77 healthy controls matched for gender, age and body mass index. Methods: Whole-body fat-free mass (FFM) and ap...

متن کامل

Effect of icodextrin dialysis solution on body weight and fat accumulation over time in CAPD patients.

BACKGROUND The purpose of this study was to analyse the changes of body composition and the effects of icodextrin dialysis solution over time on peritoneal dialysis (PD) in continuous ambulatory peritoneal dialysis (CAPD) patients. METHODS Among 183 incident patients, 75 patients finished a complete 36-month protocol. Clinical indices including daily glucose absorption and body composition, b...

متن کامل

Impact of hydration and nutrition status on the Watson formula in peritoneal dialysis patients.

Urea clearance (Kt/V urea), adjusted for total body water (TBW) using the Watson formula (TBW(Watson)), is widely used to guide peritoneal dialysis (PD) prescription and to ensure dialysis adequacy. The impact of body composition on the determination of TBW(Watson) is well established, but the effect of hydration and nutrition status on TBW(Watson) is not understood. We therefore studied the ef...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Peritoneal dialysis international : journal of the International Society for Peritoneal Dialysis

دوره 27 5  شماره 

صفحات  -

تاریخ انتشار 2007