Body composition in subjects with anorexia nervosa: bioelectrical impedance analysis and dual-energy X-ray absorptiometry.

نویسندگان

  • G Bonaccorsi
  • A Bassetti
  • S Chiari
  • P Dirindelli
  • C Lorini
  • C Menicalli
  • F Santomauro
  • M G Martinetti
چکیده

OBJECTIVE To evaluate the applicability and validity of bioelectrical impedance analysis (BIA) compared with dual-energy X-ray absorptiometry (DXA) in a population of girls with restrictive anorexia nervosa (AN). METHODS A total of 30 girls (11-19 years old) with AN were enrolled. DXA and BIA (BIA software and the Deurenberg equations) were used to estimate the body composition. The correlation between the methods was assessed by Pearson's correlation coefficient and the Bland-Altman method. RESULTS The mean FFM estimates were 33.2 kg (BIA software), 32.8 kg (BIA, Deurenberg equation) and 33.1 kg (DXA). The mean FM values were 5.6 kg (BIA software), 6.2 kg (BIA, Deurenberg equation) and 6.4 kg (DXA). There was a high correlation between the FFM values estimated with the two methods (BIA software vs DXA r=0.917, p<0.001; Deurenberg equation vs DXA r=0.931, p<0.001). For the FFM, the limits of agreement were equal to ±3.34 kg for the BIA software and ±2.96 kg for the Deurenberg equation. For the FM, the limits of agreement were equal to ±4.60 kg for the BIA software and ±3.82 kg for the Deurenberg equation. CONCLUSION The results show a good correlation between DXA and BIA. BIA seems to be a valid alternative for epidemiological and clinical evaluations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparisons of a Multi-Frequency Bioelectrical Impedance Analysis to the Dual-Energy X-Ray Absorptiometry Scan in Healthy Young Adults Depending on their Physical Activity Level

This study aimed at comparing BIA and DXA results in assessing body composition in young adults depending on their physical activity level. Eighty healthy 19-30 years old subjects were enrolled and their body composition (Fat Mass and Fat-Free Mass) was assessed by dual-energy X-ray absorptiometry (DXA) and by a newly developed Bioelectrical Impedance Analyzer (BIA - Tanita MC780). A seven-day ...

متن کامل

Estimation of body composition from bioelectrical impedance of body segments: comparison with dual-energy X-ray absorptiometry.

In twenty-eight healthy subjects, ten men and eighteen women, with a range in body mass index (BMI) of 17.9-31.6 kg/m2 and an age range 20-60 years, body composition was estimated by dual-energy X-ray absorptiometry (DEXA), skinfold anthropometry (SFA) and bioelectrical impedance analysis (BIA) of the 'whole body' and body segments. In thirteen subjects muscle mass was also estimated by 24 h ur...

متن کامل

Bioelectrical impedance analysis (BIA) using bipolar foot electrodes in the assessment of body composition in Type 2 diabetes mellitus.

The use of bioelectrical impedance analysis (BIA) for determining human body composition is widely accepted as a safe, rapid, and reliable technique. Although this technique has been validated in normal and obese individuals, only limited studies have been done in special populations. The use of BIA for the measurement of body composition in Type 2 (non-insulin dependent) diabetic patients woul...

متن کامل

Segmental body composition assessed by bioelectrical impedance analysis and DEXA in humans.

The present study assessed the relative contribution of each body segment to whole body fat-free mass (FFM) and impedance and explored the use of segmental bioelectrical impedance analysis to estimate segmental tissue composition. Multiple frequencies of whole body and segmental impedances were measured in 51 normal and overweight women. Segmental tissue composition was independently assessed b...

متن کامل

New bioelectrical impedance formula for patients with respiratory insufficiency: comparison to dual-energy X-ray absorptiometry.

Malnutrition in patients with severe respiratory insufficiency can lead to severe complications, justifying the use of objective nutritional assessment techniques, such as bioelectrical impedance analysis (BIA), which is an easy, noninvasive method of measuring body composition. The purpose of this study was to develop, and validate against dual-energy X-ray absorptiometry (DXA), a BIA formula ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Eating and weight disorders : EWD

دوره 17 4  شماره 

صفحات  -

تاریخ انتشار 2012