An improved 3D shape context based non-rigid registration method and its application to small animal skeletons registration
نویسندگان
چکیده
3D shape context is a method to define matching points between similar shapes. It can be used as a pre-processing step in a non-rigid registration. The main limitation of the method is point mismatching, which includes long geodesic distance mismatch causing wrong topological structure, and neighbors crossing mismatch between two adjacent points. In this paper, we propose a topological structure verification method to correct the long geodesic distance mismatch and a correspondence field smoothing method to correct the neighbors crossing mismatch. A robust 3D shape context model is generated and further combined with thin-plate spline model for non-rigid registration. The method was tested on phantoms and applied to rat hind limb and mouse hind limb skeletons registration from micro-CT images. Errors between the registered surfaces were reduced by using the proposed method. The robustness of the method is demonstrated.
منابع مشابه
A Novel Subsampling Method for 3D Multimodality Medical Image Registration Based on Mutual Information
Mutual information (MI) is a widely used similarity metric for multimodality image registration. However, it involves an extremely high computational time especially when it is applied to volume images. Moreover, its robustness is affected by existence of local maxima. The multi-resolution pyramid approaches have been proposed to speed up the registration process and increase the accuracy of th...
متن کاملبهبود سرعت "انطباق مبتنی بر روش برش گراف" جهت انطباق غیر صلب تصاویر تشدید مغناطیسی مغز
Image processing methods, which can visualize objects inside the human body, are of special interests. In clinical diagnosis using medical images, integration of useful data from separate images is often desired. The images have to be geometrically aligned for better observation. The procedure of mapping points from the reference image to corresponding points in the floating image is called Ima...
متن کاملCompensation of brain shift during surgery using non-rigid registration of MR and ultrasound images
Background: Surgery and accurate removal of the brain tumor in the operating room and after opening the scalp is one of the major challenges for neurosurgeons due to the removal of skull pressure and displacement and deformation of the brain tissue. This displacement of the brain changes the location of the tumor relative to the MR image taken preoperatively. Methods: This study, which is done...
متن کاملMediated Spatiotemporal Registration of Cardiac DCE-MRI and Coronary MR Angiography
Patient-specific correlation of perfusion defects to coronary arteries which are responsible for blood supply in the affected territories has the potential to improve accuracy of diagnosis and intervention planning. The correlation of coronary arteries and perfusion defects can be established through registration of 3D angiography and 2D perfusion datasets. However, cardiac cycle phase mismatch...
متن کاملOptimized co-registration method of Spinal cord MR Neuroimaging data analysis and application for generating multi-parameter maps
Introduction: The purpose of multimodal and co-registration In MR Neuroimaging is to fuse two or more sets images (T1, T2, fMRI, DTI, pMRI, …) for combining the different information into a composite correlated data set in order to visualization, re-alignment and generating transform to functional Matrix. Multimodal registration and motion correction in spinal cord MR Neuroimag...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society
دوره 34 4 شماره
صفحات -
تاریخ انتشار 2010