The Effect of Biceps Reattachment Site on Moment Arm

ثبت نشده
چکیده

Introduction: Avulsion of the distal biceps tendon from the tuberosity occurs mostly in middle-aged males resulting from eccentric loading of the flexed, supinated forearm . When non-operative treatment is chosen, supination strength decreases by 50% and flexion strength is reduced by 35-40% . Surgical repair has been shown to be a better alternative than non-operative treatments for restoration of strength and endurance . Current surgical methods include one and two incision repair techniques in which the tendon is reattached to the anterior or posterior aspect of the tuberosity respectively. Methods of attachment of the tendon include using sutures, suture anchors and endobuttons. Although studies have examined the fixation strength of these types of repairs, little has been done to examine the effect that attachment location has on functional outcome of the repair. The objective of this project is to determine the impact that the reattachment location has on torque generating ability of the forearm described as its moment arm. The results of this study can help surgeons gain a better understanding of how to optimize the repair and thereby improve the expected outcome of patients with distal biceps injuries. Methods: A total of 6 frozen upper extremity cadaveric specimens (5 male), with an average age of 60 (36-83) years, were used. The specimens included the full forearm from the hand to the mid-humerus proximally. Specimens with medical histories of rheumatoid arthritis, degenerative joint disease or any orthopaedic anomaly were excluded. Prior to the day of testing, each specimen was allowed to thaw overnight at room temperature and kept moist with normal saline. An elbow simulator, that includes computer controlled actuators to exert known loads on the forearm applied through the biceps tendon, was adapted to a device capable of measuring isometric forearm torque generated by cadaveric elbows. The device has an adjustable shaft that attaches to a plate mounted on the distal radius. The other end of the shaft transmits load to a torque sensor (Transducer Techniques, Temecula, CA) which is wired into a computer data acquisition system. Each specimen was mounted in the elbow simulator with the humerus and ulna fixed firmly to the frame at 90° of flexion. The proximal end of the distal biceps tendon was attached to an actuator using 80lb test line. The adjustable shaft was attached to the distal radius plate. The forearm was then rotated and locked into three positions: 60° supination, neutral and 60° pronation. The biceps tendon was loaded to 15 lbs, and the torque was measured for the native tendon attachment. Then the biceps tendon was detached and attached at four different locations. For each forearm position, each test was replicated three times. With the arm fully supinated, the borders of the radial tuberosity were identified, and the proximal and distal border lines were drawn (Figure 1). The borders were defined at the point where the bone geometry of the radius begins to exhibit slight concave curvature. The length of the tuberosity borders was measured and their midpoints were marked. A line connecting the two midpoints was used to define the center axis line. The highest point (apex) on the tuberosity at the tendon-bone interface was identified using calipers. A medial to lateral line, parallel to the tuberosity border lines, was drawn to define the apex diameter line. Using these markings as a guide, three drill holes were systematically placed in the radius. Location “A” was placed on the apex diameter line at the native tendon insertion. Location “B” was drilled at the intersection of the center axis and apex diameter lines. Location “C” is the same as “B” except that the tendon wrapped around the tuberosity and attached on the posterior side of the radius. Location “D” was drilled at the most ulnar point on the proximal border line.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of biceps reattachment site.

BACKGROUND We hypothesize that an anatomic repair of the distal biceps tendon would recreate native tendon moment arm and forearm rotation, while a nonanatomic insertion would compromise moment arm and forearm rotation. METHODS Isometric supination torque was measured at 60° of pronation, neutral, and 60° of supination for the native distal biceps tendon and 4 repair points in 6 cadaveric spe...

متن کامل

The Effect of Biceps Reattachment Site on Moment Arm

Avulsion of the distal biceps tendon from the tuberosity occurs mostly in middle-aged males resulting from eccentric loading of the flexed, supinated forearm [1]. When non-operative treatment is chosen, supination strength decreases by 50% and flexion strength is reduced by 35-40% [2]. Surgical repair has been shown to be a better alternative than non-operative treatments for restoration of str...

متن کامل

Association between contraction-induced increases in elbow flexor muscle thickness and distal biceps brachii tendon moment arm depends on the muscle thickness measurement site.

The purpose of this study was to investigate how the contraction-induced increase in distal biceps brachii tendon moment arm is related to that in elbow flexor muscle thickness, with a specific emphasis on the influence of the site-related differences in muscle thickness. The moment arm and muscle thickness were determined from sagittal and cross-sectional images, respectively, of the right arm...

متن کامل

Variation of muscle moment arms with elbow and forearm position.

We hypothesized that the moment arms of muscles crossing the elbow vary substantially with forearm and elbow position and that these variations could be represented using a three-dimensional computer model. Flexion/extension and pronation/supination moment arms of the brachioradialis, biceps, brachialis, pronator teres, and triceps were calculated from measurements of tendon displacement and jo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010