Capacitor Current Feedback-Based Active Resonance Damping Strategies for Digitally-Controlled Inductive-Capacitive-Inductive-Filtered Grid-Connected Inverters

نویسندگان

  • Iman Lorzadeh
  • Hossein Askarian Abyaneh
  • Mehdi Savaghebi
  • Alireza Bakhshai
  • Josep M. Guerrero
چکیده

Inductive-capacitive-inductive (LCL)-type line filters are widely used in grid-connected voltage source inverters (VSIs), since they can provide substantially improved attenuation of switching harmonics in currents injected into the grid with lower cost, weight and power losses than their L-type counterparts. However, the inclusion of third order LCL network complicates the current control design regarding the system stability issues because of an inherent resonance peak which appears in the open-loop transfer function of the inverter control system near the control stability boundary. To avoid passive (resistive) resonance damping solutions, due to their additional power losses, active damping (AD) techniques are often applied with proper control algorithms in order to damp the LCL filter resonance and stabilize the system. Among these techniques, the capacitor current feedback (CCF) AD has attracted considerable attention due to its effective damping performance and simple implementation. This paper thus presents a state-of-the-art review of resonance and stability characteristics of CCF-based AD approaches for a digitally-controlled LCL filter-based grid-connected inverter taking into account the effect of computation and pulse width modulation (PWM) delays along with a detailed analysis on proper design and implementation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stability Improvement of Grid-connected Converter with LCL Filter based on Capacitor Current Active Damping by Computational Delay Reduction

Nowadays, LCL filters utilization to suppress the grid-connected inverter switching harmonics is expanding and various methods such as capacitor current active damping scheme could be investigated to damp out these harmonics. However, the computational delays including control system, and PWM switching delays have significant effect on damping system stability. In most of LCL filter parameter d...

متن کامل

Power Quality Improvement in a Cascaded Multilevel Inverter Interfaced Grid Connected System Using a Modified Inductive–Capacitive–Inductive Filter with Reduced Power Loss and Improved Harmonic Attenuation

Recently, multilevel inverters are more researched due to the advantages they offer over conventional voltage source inverters in grid connected applications. Passive filters are connected at the output of these inverters to produce sinusoidal waveforms with reduced harmonics and to satisfy grid interconnection standard requirements. This work proposes a new passive filter topology for a pulse ...

متن کامل

H∞ Repetitive Control Based on Active Damping with Reduced Computation Delay for LCL-Type Grid-Connected Inverters

In the paper, the H∞ repetitive current control scheme based on active damping along with the design method is proposed for three-phase grid-connected inverters with inductor-capacitor-inductor (LCL) filters. The control scheme aims to reduce the harmonic distortion of the output currents and achieve better efficiency. The design method introduces capacitor-current-feedback active damping into ...

متن کامل

The Design of a New Double Loop Controller For Simultaneous Adjustment of Input and Output Voltages of Single-Phase Grid-Connected Inverter

Although LCL filters are used widely in the grid connected inverters to reduce high-orderharmonics, such a system increases system order and therefore sustainable design of closed-loopcontroller system will be complicated. Recently, the single-loop control strategy has beensuggested for L or LC filter based grid-connected inverters. However, the use of single-loopcontrol directly in LCL filter-...

متن کامل

Aalborg Universitet Analysis and Design of Improved Weighted Average Current Control Strategy for LCL- Type Grid-Connected Inverters

The LCL grid-connected inverter has the ability to attenuate the high-frequency current harmonics. However, the inherent resonance of the LCL filter affects the system stability significantly. To damp the resonance effect, the dual-loop current control can be used to stabilize the system. The grid current plus capacitor current feedback system is widely used for its better transient response an...

متن کامل