Epoch length to accurately estimate the amplitude of interference EMG is likely the result of unavoidable amplitude cancellation

نویسندگان

  • Kevin G. Keenan
  • Francisco J. Valero Cuevas
چکیده

Researchers and clinicians routinely rely on interference electromyograms (EMGs) to estimate muscle forces and command signals in the neuromuscular system (e.g., amplitude, timing, and frequency content). The amplitude cancellation intrinsic to interference EMG, however, raises important questions about how to optimize these estimates. For example, what should the length of the epoch (time window) be to average an EMG signal to reliably estimate muscle forces and command signals? Shorter epochs are most practical, and significant reductions in epoch have been reported with high-pass filtering and whitening. Given that this processing attenuates power at frequencies of interest (< 250 Hz), however, it is unclear how it improves the extraction of physiologically-relevant information. We examined the influence of amplitude cancellation and high-pass filtering on the epoch necessary to accurately estimate the "true" average EMG amplitude calculated from a 28 s EMG trace (EMG(ref)) during simulated constant isometric conditions. Monte Carlo iterations of a motor-unit model simulating 28 s of surface EMG produced 245 simulations under 2 conditions: with and without amplitude cancellation. For each simulation, we calculated the epoch necessary to generate average full-wave rectified EMG amplitudes that settled within 5% of EMG(ref.) For the no-cancellation EMG, the necessary epochs were short (e.g., < 100 ms). For the more realistic interference EMG (i.e., cancellation condition), epochs shortened dramatically after using high-pass filter cutoffs above 250 Hz, producing epochs short enough to be practical (i.e., < 500 ms). We conclude that the need to use long epochs to accurately estimate EMG amplitude is likely the result of unavoidable amplitude cancellation, which helps to clarify why high-pass filtering (> 250 Hz) improves EMG estimates.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Amplitude cancellation reduces the size of motor unit potentials averaged from the surface EMG.

The purpose of the study was to evaluate the influence of selected physiological parameters on amplitude cancellation in the simulated surface electromyogram (EMG) and the consequences for spike-triggered averages of motor unit potentials derived from the interference and rectified EMG signals. The surface EMG was simulated from prescribed recruitment and rate coding characteristics of a motor ...

متن کامل

EMG-based Fatigue Assessment During Endurance Testing With Different VT Protocols

BACKGROUND: Muscle fatigue can be defined as the failure of a muscle to maintain a reasonably expected force output. The multivariate approach to fatigue assessment is used because the multiple (EMG) feature provides more information than anyone. OBJECTIVE: This study presents a method of assessing muscle fatigue during endurance testing at 50% maximal voluntary contraction (MVC) using electro...

متن کامل

Motor amplitude of median nerve with stimulation in the palm a reliable indicator for axonal loss in carpal tunnel syndrome

Background and Aim: The present study aimed to use the median nerve compound muscle action potential (CMAP) amplitude by stimulation at the palm instead of abductor pollicis brevis (APB) needle electromyography (EMG) for determining a sign of axonal loss in patients with carpal tunnel syndrome (CTS). Methods and Materials/Patients: This study was performed on 180 patients with CTS referred to ...

متن کامل

Amplitude cancellation of motor-unit action potentials in the surface electromyogram can be estimated with spike-triggered averaging.

The study presents analytical, simulation, and experimental analyses of amplitude cancellation of motor-unit action potentials (APs) in the interference electromyogram (EMG) and its relation to the size of the spike-triggered average (STA) EMG. The amount of cancellation of motor-unit APs decreases monotonically as a function of the ratio between the root mean square (RMS) of the motor-unit AP ...

متن کامل

معرفی روش استفاده از سیگنال مکانومیوگرام در ارزیابی عملکرد عضلات

  Background and aims   Recordings of electrical activity in the muscle and surface electromyography (EMG) have been widely used in the field of applied physiology. In parallel to  recording of the EMG, the detectable low-frequency vibration signal generated by the skeletal  muscle has been known and well documented. As the nature of the signal has been progressively   revealed, the term of mec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Biomedical signal processing and control

دوره 3 2  شماره 

صفحات  -

تاریخ انتشار 2008