Early results of the less invasive stabilization system for mechanically unstable fractures of the distal femur (AO/OTA types A2, A3, C2, and C3).
نویسندگان
چکیده
OBJECTIVES Historically, mechanically unstable fractures of the distal femur have been difficult to treat. Problems such as varus collapse, malunion, and nonunion frequently resulted before fixed-angle plates and indirect reduction techniques were popularized. More recently, the Less Invasive Stabilization System, or LISS (Synthes, Paoli, PA), has been designed to combine these 2 approaches with the intended goals of achieving adequate stable fixation and early healing. Early clinical results for the femoral Less Invasive Stabilization System have been promising. The purpose of this study is to evaluate the clinical results of patients with high energy, mechanically unstable fractures of the distal femur treated with the Less Invasive Stabilization System. DESIGN Retrospective analysis of a treatment protocol, consecutive patient series. SETTING Busy level II trauma center. PATIENTS /PARTICIPANTS: Twenty-six patients with 27 high-energy AO/OTA types A2, A3, C2, and C3 fractures of the distal femur. INTERVENTION Treatment with indirect fracture reduction and internal distal femoral fixation using the Less Invasive Stabilization System. MAIN OUTCOME MEASUREMENTS Clinical and radiographic assessment. RESULTS Twenty-one patients with 22 fractures were available for evaluation at an average 19 months postinjury (range 12-35 months). The mechanism of injury included 12 motor vehicle collisions, 4 high falls, 5 motorcycle crashes, and 1 bicyclist struck by a car. Twenty patients had associated injuries. Six fractures were open. All fractures were comminuted; according to the AO/OTA fracture classification there were 4 A2, 3 A3, 12 C2, and 3 C3 fractures. All fractures healed without secondary surgeries at a mean of 13 weeks (range 7-16 weeks). There were no cases of failed fixation, implant breakage, or infection. Average joint line orientation relative to the femoral shaft axis (valgus) measured 99 degrees on postoperative radiographs and 99 degrees on final radiographs. A comparison of postoperative to healed final radiographs for each femur demonstrated no case with greater than a 3 degrees difference in either varus or valgus. Complications included 1 mal-union where the fracture was fixed in 8 degrees of valgus and 2 cases of external rotation between 10 degrees and 15 degrees. Painful hardware occurred in 4 patients, of which 3 underwent implant removal. The average knee range of motion was 5 degrees to 114 degrees. CONCLUSIONS The Less Invasive Stabilization System allows for stable fixation and facilitates early healing in mechanically unstable high-energy fractures of the distal femur. There were no patients with fixation failure, varus collapse, or nonunion in this "at-risk" population. This treatment safely allows for immediate postoperative initiation of joint mobility and the progression of weight bearing with early radiographic signs of healing.
منابع مشابه
Modified Tension Band Wiring in Adult Distal Humeral Fracture Types A2 and C1
Background: Distal humeral fractures accounts for approximately 2% of all fractures and nearly one-third of humeralfractures in adults. In this regard, Modified Tension Bind Wiring (MTBW) technique was used for the fixation of the distalhumeral fractures type A2 and C1 (AO) to evaluate the early movement and complications of the patients.Methods: This study was conducted on 25...
متن کاملFunctional outcome of distal femoral fractures treated by minimally invasive surgery using locking condylar plate
Correspondence should be sent to: [email protected] ABSTRACT Background: The management of distal femoral fractures has presented significant challenge to Orthopaedic surgeons. A wide medullary canal, thin cortex and poor bone stock make stable internal fixation in these fractures difficult. Severe soft tissue damage, extensive comminution, intrarticular extension and injury to quadriceps mecha...
متن کاملOpen biological reduction and a locking compression plate for distal femoral fractures: a review of 40 cases.
OBJECTIVE To determine the clinical results of patients with comminuted fractures of the distal femur treated by open biological reduction using an indirect reduction technique and locking compression plate (LCP) without primary bone grafting. MATERIAL AND METHOD Prospective observation was conducted with 40 patients (24 males and 16 females), average age 48.7 years (range 20-81), with distal...
متن کاملMorphology and fixation pitfalls of a highly unstable intertrochanteric fracture variant.
PURPOSE To describe a variant of intertrochanteric fracture not well-characterised in the existing classification systems. METHODS 10 women and 2 men aged 59 to 98 (median, 80) years with intertrochanteric fractures characterised by a low intertrochanteric fracture, a basicervical fracture fragment, and a thin or fractured lateral wall with greater trochanteric comminution were reviewed. RE...
متن کاملEfficacy of closed reduction and maintenance of surgical outcome in plaster cast immobilization in different types of distal radius fractures.
BACKGROUND The aim of this paper is to evaluate the results maintaining after closed reduction of distal radius fracture and to assess difficulties in restoration of the articular surface continuity with reference to the type of fracture according to the AO classification. MATERIAL AND METHODS 65 patients were included in the study (40 female, 25 male), mean age of 59 years (19-84), diagnosed...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of orthopaedic trauma
دوره 18 8 شماره
صفحات -
تاریخ انتشار 2004