Cardiac helical CT involving a low-radiation-dose protocol with a 100-kVp setting

نویسندگان

  • Yuji Iyama
  • Takeshi Nakaura
  • Koichi Yokoyama
  • Masafumi Kidoh
  • Yasuyuki Yamashita
چکیده

To compare the radiation dose and image quality of retrospective electrocardiogram (ECG)-gated cardiac computed tomography (CT) between a 100-kVp protocol, hybrid iterative reconstruction (HIR), and display preset optimization and the 120-kVp protocol.We prospectively enrolled 100 patients with tachycardia or atrial fibrillation scanned retrospective ECG-gated cardiac CT. We randomly assigned 50 patients to the 120-kVp protocol and 50 patients to the 100-kVp protocol. We compared effective doses (EDs) between the two protocols. The 120-kVp images were post-processed using filtered back projection (FBP). The 100-kVp images were post-processed using FBP (100-kVp protocol) and HIR (i-100-kVp protocol). We compared attenuation of the ascending aorta, signal-to-noise ratio (SNR), and image noise between the 120-kVp, 100-kVp, and i-100-kVp protocols. We performed qualitative image analysis for the 120-kVp and i-100-kVp protocols.ED of the 100-kVp protocol (4.4 ± 0.4 mSv) was 76% lower than that of the 120-kVp protocol (18.4 ± 0.6 mSv). Attenuations of the 100-kVp (549.1 ± 73.8 HU) and i-100-kVp (550.5 ± 73.7 HU) protocols were higher than that of the120-kVp protocol (437.3 ± 55.7 HU). Image noise of the 100-kVp (53.6 ± 18.5 HU) and i-100-kVp (30.9 ± 8.6 HU) protocols were higher than that of the120-kVp protocol (23.8 ± 5.7 HU). There was no significant difference in SNR and the result of qualitative image analysis between the 120-kVp and i-100-kVp protocols.The 100-kVp protocol with HIR reduced the 76% radiation dose while preserving the image quality compared with the conventional 120-kVp protocol on retrospective ECG-gated cardiac CT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of Radiation Dose in Cranial Computed Tomography among Adults: Assessment of Radiation Dose against Image Quality

Introduction: The rapid use of computed tomography (CT) scan is of great concern, due to increase in patients’ dose. Optimization of CT protocol is a vital issue in dose reduction. This study aimed to optimize radiation dose in cranial CT and assess modifications in image quality under radiation dose reduction. Material and Methods: A poly(me...

متن کامل

Radiation dose reduction based on CNR index with low-tube voltage scan for pediatric CT scan: experimental study using anthropomorphic phantoms

BACKGROUND To figure out the relationship between image noise and contrast noise ratio (CNR) at different tube voltages, using anthropomorphic new-born and 1-year-old phantoms, and to discuss the feasibility of radiation dose reduction, based on the obtained CNR index from image noise. We performed helical scans of the anthropomorphic new-born and 1-year-old phantoms. The CT numbers of the simu...

متن کامل

Reducing radiation doses in female breast and lung during CT examinations of thorax: A new technique in two scanners

Background: Chest CT is a commonly used examination for the diagnosis of lung diseases, but a breast within the scanned field is nearly never the organ of interest.Objective: The purpose of this study is to compare the female breast and lung doses using split and standard protocols in chest CT scanning.Materials and Methods: The sliced chest and breast female phantoms were used. CT exams were p...

متن کامل

The Image Quality and Radiation Dose of 100-kVp versus 120-kVp ECG-Gated 16-Slice CT Coronary Angiography

OBJECTIVE This study was conducted to assess the feasibility of performing 100-kVp electrocardiogram (ECG)-gated coronary CT angiography, as compared to 120-kVp ECG-gated coronary CT angiography. MATERIALS AND METHODS We retrospectively evaluated one hundred eighty five gender- and body mass index-matched 16-slice coronary CT sets of data, which were obtained using either 100 kVp and 620 effe...

متن کامل

Ultralow-dose chest computed tomography for pulmonary nodule detection: first performance evaluation of single energy scanning with spectral shaping.

PURPOSE The purpose of this study was to evaluate the image quality and sensitivity of ultralow radiation dose single-energy computed tomography (CT) with tin filtration for spectral shaping and iterative reconstructions for the detection of pulmonary nodules in a phantom setting. METHODS Single-energy CT was performed using third-generation dual-source CT (SOMATOM Force; 2 × 192 slices) at 7...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 95  شماره 

صفحات  -

تاریخ انتشار 2016