Cardiac helical CT involving a low-radiation-dose protocol with a 100-kVp setting
نویسندگان
چکیده
To compare the radiation dose and image quality of retrospective electrocardiogram (ECG)-gated cardiac computed tomography (CT) between a 100-kVp protocol, hybrid iterative reconstruction (HIR), and display preset optimization and the 120-kVp protocol.We prospectively enrolled 100 patients with tachycardia or atrial fibrillation scanned retrospective ECG-gated cardiac CT. We randomly assigned 50 patients to the 120-kVp protocol and 50 patients to the 100-kVp protocol. We compared effective doses (EDs) between the two protocols. The 120-kVp images were post-processed using filtered back projection (FBP). The 100-kVp images were post-processed using FBP (100-kVp protocol) and HIR (i-100-kVp protocol). We compared attenuation of the ascending aorta, signal-to-noise ratio (SNR), and image noise between the 120-kVp, 100-kVp, and i-100-kVp protocols. We performed qualitative image analysis for the 120-kVp and i-100-kVp protocols.ED of the 100-kVp protocol (4.4 ± 0.4 mSv) was 76% lower than that of the 120-kVp protocol (18.4 ± 0.6 mSv). Attenuations of the 100-kVp (549.1 ± 73.8 HU) and i-100-kVp (550.5 ± 73.7 HU) protocols were higher than that of the120-kVp protocol (437.3 ± 55.7 HU). Image noise of the 100-kVp (53.6 ± 18.5 HU) and i-100-kVp (30.9 ± 8.6 HU) protocols were higher than that of the120-kVp protocol (23.8 ± 5.7 HU). There was no significant difference in SNR and the result of qualitative image analysis between the 120-kVp and i-100-kVp protocols.The 100-kVp protocol with HIR reduced the 76% radiation dose while preserving the image quality compared with the conventional 120-kVp protocol on retrospective ECG-gated cardiac CT.
منابع مشابه
Optimization of Radiation Dose in Cranial Computed Tomography among Adults: Assessment of Radiation Dose against Image Quality
Introduction: The rapid use of computed tomography (CT) scan is of great concern, due to increase in patients’ dose. Optimization of CT protocol is a vital issue in dose reduction. This study aimed to optimize radiation dose in cranial CT and assess modifications in image quality under radiation dose reduction. Material and Methods: A poly(me...
متن کاملRadiation dose reduction based on CNR index with low-tube voltage scan for pediatric CT scan: experimental study using anthropomorphic phantoms
BACKGROUND To figure out the relationship between image noise and contrast noise ratio (CNR) at different tube voltages, using anthropomorphic new-born and 1-year-old phantoms, and to discuss the feasibility of radiation dose reduction, based on the obtained CNR index from image noise. We performed helical scans of the anthropomorphic new-born and 1-year-old phantoms. The CT numbers of the simu...
متن کاملReducing radiation doses in female breast and lung during CT examinations of thorax: A new technique in two scanners
Background: Chest CT is a commonly used examination for the diagnosis of lung diseases, but a breast within the scanned field is nearly never the organ of interest.Objective: The purpose of this study is to compare the female breast and lung doses using split and standard protocols in chest CT scanning.Materials and Methods: The sliced chest and breast female phantoms were used. CT exams were p...
متن کاملThe Image Quality and Radiation Dose of 100-kVp versus 120-kVp ECG-Gated 16-Slice CT Coronary Angiography
OBJECTIVE This study was conducted to assess the feasibility of performing 100-kVp electrocardiogram (ECG)-gated coronary CT angiography, as compared to 120-kVp ECG-gated coronary CT angiography. MATERIALS AND METHODS We retrospectively evaluated one hundred eighty five gender- and body mass index-matched 16-slice coronary CT sets of data, which were obtained using either 100 kVp and 620 effe...
متن کاملUltralow-dose chest computed tomography for pulmonary nodule detection: first performance evaluation of single energy scanning with spectral shaping.
PURPOSE The purpose of this study was to evaluate the image quality and sensitivity of ultralow radiation dose single-energy computed tomography (CT) with tin filtration for spectral shaping and iterative reconstructions for the detection of pulmonary nodules in a phantom setting. METHODS Single-energy CT was performed using third-generation dual-source CT (SOMATOM Force; 2 × 192 slices) at 7...