Heterogeneous electron-transfer kinetics with synchrotron 57Fe Mossbauer spectroscopy

نویسندگان

  • J. E. Amonette
  • Ravi K. Kukkadapu
  • E. E. Alp
  • W. Sturhahn
  • T. S. Toellner
چکیده

In the first known kinetic application of the technique, synchrotron Fe-Mössbauer spectroscopy was used to follow the rate of heterogeneous electron transfer between aqueous reagents and a solid phase containing Fe. The solid, a synthetic Fe-enriched Fe(III)-bearing pyroaurite-like phase having terephthalate (TA) in the interlayer [Mg3Fe(OH)8(TA)0.5 2H2O], was reduced by Na2S2O4 and then reoxidized by K2Cr2O7 by means of a novel flow-through cell. Synchrotron Mössbauer spectra were collected in the time domain at 30-s intervals. Integration of the intensity obtained during a selected time interval in the spectra allowed sensitive determination of Fe(II) content as a function of reaction time. Analysis of reaction end member specimens by both the synchrotron technique and conventional Mössbauer spectroscopy yielded comparable values for Mössbauer parameters such as center shift and Fe(II)/Fe(III) area ratios. Slight differences in quadrupole splitting values were observed, however. A reactive diffusion model was developed that fit the experimental Fe(II) kinetic data well and allowed the extraction of second-order rate constants for each reaction. Thus, in addition to rapidly collecting high quality Mössbauer data, the synchrotron technique seems well suited for aqueous rate experiments as a result of the penetrating power of 14.4 keV X-rays and high sensitivity to Fe valence state. Copyright © 2003 Elsevier Science Ltd

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Kinetics inversion of chloro-olefine in the solid acid system

The reaction kinetics of the isomerization 3,4-dichlorobutene-1 to 1,4-dichlorobutene-2 was investigated by using gas-liquid chromatography method in the presence of Fe2O3/MgO as solid catalyst in the temperature range 25-55°C. Fe2O3/MgO has been prepared by the support saturation method, tested in the isomerization of 3, 4-dichlorobutene-1 into 1, 4-dichlorobutene-2. This catalyst shows a high...

متن کامل

Kinetics inversion of chloro-olefine in the solid acid system

The reaction kinetics of the isomerization 3,4-dichlorobutene-1 to 1,4-dichlorobutene-2 was investigated by using gas-liquid chromatography method in the presence of Fe2O3/MgO as solid catalyst in the temperature range 25-55°C. Fe2O3/MgO has been prepared by the support saturation method, tested in the isomerization of 3, 4-dichlorobutene-1 into 1, 4-dichlorobutene-2. This catalyst shows a high...

متن کامل

Mossbauer Spectroscopy of Iron Biomineralization Products in Magnetotactic Bacteria

Mcissbauer spectroscopy is a nuclear i-rav resonance technique that has been extensively tv!i 'iill' s,,'stems. applied to the study of the electronic properties of iron in biological '. The power of the technique lies in its sensitivity to the effects of the physical environment (nature ]18 lw and disposition of ligands, magnetic structure, etc.) on 57Fe nuclei. Moreover, it is sensitive ' onl...

متن کامل

Electronic structure of the unique [4Fe-3S] cluster in O2-tolerant hydrogenases characterized by 57Fe Mossbauer and EPR spectroscopy.

Iron-sulfur clusters are ubiquitous electron transfer cofactors in hydrogenases. Their types and redox properties are important for H(2) catalysis, but, recently, their role in a protection mechanism against oxidative inactivation has also been recognized for a [4Fe-3S] cluster in O(2)-tolerant group 1 [NiFe] hydrogenases. This cluster, which is uniquely coordinated by six cysteines, is situate...

متن کامل

57Fe Mössbauer Spectroscopy of Zinc Ferrite Prepared by a Variety of Synthetic Methods

Confirmation of the suggestion of B site zn2+ in nanocrystalline ZnFe204 has heen sought through X-ray diffraction, 5 7 ~ e Miissbauer spectroscopy, magnetic susceptibility and TEM measurements on bulk and nanocrystalline samples prepared by different techniques. Measurements on bulk samples are in agreement with previously reported ones. Samples prepared at low temperature from solutions of sa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017