Line Protection with Overcurrent Relays
ثبت نشده
چکیده
259 Lines are protected by overcurrent-, distance-, or pilot-relaying equipment, depending on the requirements. Overcurrent relaying is the simplest and cheapest, the most difficult to apply, and the quickest to need readjustment or even replacement as a system changes. It is generally used for phaseand ground-fault protection on station-service and distribution circuits in electric utility and in industrial systems, and on some subtransmission lines where the cost of distance relaying cannot be justified. It is used for primary ground-fault protection on most transmission lines where distance relays are used for phase faults, and for ground back-up protection on most lines having pilot relaying for primary protection. However, distance relaying for ground-fault primary and back-up protection of transmission lines is slowly replacing overcurrent relaying. Overcurrent relaying is used extensively also at power-transformer locations for externa-fault back-up protection, but here, also, there is a trend toward replacing overcurrent with distance relays.
منابع مشابه
Considering Pilot Protection in the Optimal Coordination of Distance and Directional Overcurrent Relays
The aim of the relay coordination is that protection systems detect and isolate the faulted part as fast and selective as possible. On the other hand, in order to reduce the fault clearing time, distance protection relays are usually equipped with pilot protection schemes. Such schemes can be considered in the distance and directional overcurrent relays (D&DOCRs) coordination to achieve faster ...
متن کاملA Novel Fuzzy and Artificial Neural Network Representation of Overcurrent Relay Characteristics
Accurate models of Overcurrent (OC) with inverse time relay characteristics play an important role for coordination of power system protection schemes. This paper proposes a new method for modeling OC relays curves. The model is based on fuzzy logic and artificial neural networks. The feed forward multilayer perceptron neural network is used to calculate operating times of OC relays for various...
متن کاملOptimal Coordination of Distance and Directional Overcurrent Relays Considering Different Network Topologies
Most studies in relay coordination have focused solely on coordination of overcurrent relays while distance relays are used as the main protection of transmission lines. Since, simultaneous coordination of these two types of relays can provide a better protection, in this paper, a new approach is proposed for simultaneous coordination of distance and directional overcurrent relays (D&DOCRs). Al...
متن کاملهماهنگی بهینه رله های اضافه جریان جهتی در شبکه های توزیع با در نظر گرفتن پایداری گذرای منابع تولید پراکنده سنکرون
Integration of distributed generation (DG) into distribution networks causes some protection challenges, which can be solved by appropriate coordination of directional overcurrent relays. The optimal coordination of directional overcurrent relays is an important task to fulfill the protection requirements of the network. This paper presents an optimal coordination method for directional overcur...
متن کاملAn Integrated Protection Scheme for Distribution Systems Based on Overcurrent Relay Principle
This paper reports on the development of integrated protection for power system. The background of the development is firstly introduced, in which a centralized protection system (or relay) provides the protection of multiple power plant or a substation. A novel integrated protection scheme for distribution system based on overcurrent protection technique is described. In the proposed scheme, s...
متن کامل