Adaptive response in zebrafish embryos induced using microbeam protons as priming dose and X-ray photons as challenging dose.

نویسندگان

  • Viann Wing Yan Choi
  • Teruaki Konishi
  • Masakazu Oikawa
  • Hiroyuki Iso
  • Shuk Han Cheng
  • Kwan Ngok Yu
چکیده

In the studies reported here, a high-linear-energy-transfer (high-LET)-radiation dose was used to induce adaptive response in zebrafish embryos in vivo. Microbeam protons were used to provide the priming dose and X-ray photons were employed to provide the challenging dose. The microbeam irradiation system (Single-Particle Irradiation System to Cell, acronym as SPICE) at the National Institute of Radiological Sciences (NIRS), Japan, was employed to control and accurately quantify the number of protons at very low doses, viz., about 100 µGy. The embryos were dechorionated at 4 h post fertilization (hpf) and irradiated at 5 hpf by microbeam protons. For each embryo, ten irradiation points were arbitrarily chosen without overlapping with one another. To each irradiation point, 5, 10 or 20 protons each with an energy of 3.4 MeV were delivered. The embryos were returned back to the incubator until 10 hpf to further receive the challenging exposure, which was achieved using 2 Gy of X-ray irradiation, and then again returned to the incubator until 24 hpf for analyses. The levels of apoptosis in zebrafish embryos at 25 hpf were quantified through terminal dUTP transferase-mediated nick end-labeling (TUNEL) assay, with the apoptotic signals captured by a confocal microscope. The results revealed that 5 to 20 protons delivered at 10 points each on the embryos, or equivalently 110 to 430 µGy, could induce radioadaptive response in the zebrafish embryos in vivo.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The threshold number of protons to induce an adaptive response in zebrafish embryos.

In this study, microbeam protons were used to provide the priming dose to induce an in vivo radioadaptive response (RAR) in the embryos of zebrafish, Danio rerio, against subsequent challenging doses provided by x-ray photons. The microbeam irradiation system (Single-Particle Irradiation System to Cell, acronym SPICE) at the National Institute of Radiological Sciences (NIRS), Japan, was employe...

متن کامل

Non-induction of radioadaptive response in zebrafish embryos by neutrons

In vivo neutron-induced radioadaptive response (RAR) was studied using zebrafish (Danio rerio) embryos. The Neutron exposure Accelerator System for Biological Effect Experiments (NASBEE) facility at the National Institute of Radiological Sciences (NIRS), Japan, was employed to provide 2-MeV neutrons. Neutron doses of 0.6, 1, 25, 50 and 100 mGy were chosen as priming doses. An X-ray dose of 2 Gy...

متن کامل

Designing experimental setup and procedures for studying alpha-particle-induced adaptive response in zebrafish embryos in vivo

The present work was devoted to designing the experimental setup and the associated procedures for alpha-particle-induced adaptive response in zebrafish embryos in vivo. Thin PADC films with a thickness of 16 lm were fabricated and employed as support substrates for holding dechorionated zebrafish embryos for alpha-particle irradiation from the bottom through the films. Embryos were collected w...

متن کامل

Radiation-induced bystander and adaptive responses in cell and tissue models.

The use of microbeam approaches has been a major advance in probing the relevance of bystander and adaptive responses in cell and tissue models. Our own studies at the Gray Cancer Institute have used both a charged particle microbeam, producing protons and helium ions and a soft X-ray microprobe, delivering focused carbon-K, aluminium-K and titanium-K soft X-rays. Using these techniques we have...

متن کامل

Consider potential of gold nanoparticles with proton therapy compared with KV and MEV X-ray therapy.

Introduction: Many study shown the effectiveness dose enhancement with gold nanoparticles (GNPs), especially with low-energy x-rays. Recently, proton beam radiation therapy (PBRT) has attention as a treatment for tumors. The advantage in PBRT, which releases high dose at the controllable Bragg peak position that localized for Au target and the released dose increased in depth....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of radiation research

دوره 51 6  شماره 

صفحات  -

تاریخ انتشار 2010