A more accurate method to estimate glomerular filtration rate from serum creatinine: a new prediction equation. Modification of Diet in Renal Disease Study Group.

نویسندگان

  • A S Levey
  • J P Bosch
  • J B Lewis
  • T Greene
  • N Rogers
  • D Roth
چکیده

BACKGROUND Serum creatinine concentration is widely used as an index of renal function, but this concentration is affected by factors other than glomerular filtration rate (GFR). OBJECTIVE To develop an equation to predict GFR from serum creatinine concentration and other factors. DESIGN Cross-sectional study of GFR, creatinine clearance, serum creatinine concentration, and demographic and clinical characteristics in patients with chronic renal disease. PATIENTS 1628 patients enrolled in the baseline period of the Modification of Diet in Renal Disease (MDRD) Study, of whom 1070 were randomly selected as the training sample; the remaining 558 patients constituted the validation sample. METHODS The prediction equation was developed by stepwise regression applied to the training sample. The equation was then tested and compared with other prediction equations in the validation sample. RESULTS To simplify prediction of GFR, the equation included only demographic and serum variables. Independent factors associated with a lower GFR included a higher serum creatinine concentration, older age, female sex, nonblack ethnicity, higher serum urea nitrogen levels, and lower serum albumin levels (P < 0.001 for all factors). The multiple regression model explained 90.3% of the variance in the logarithm of GFR in the validation sample. Measured creatinine clearance overestimated GFR by 19%, and creatinine clearance predicted by the Cockcroft-Gault formula overestimated GFR by 16%. After adjustment for this overestimation, the percentage of variance of the logarithm of GFR predicted by measured creatinine clearance or the Cockcroft-Gault formula was 86.6% and 84.2%, respectively. CONCLUSION The equation developed from the MDRD Study provided a more accurate estimate of GFR in our study group than measured creatinine clearance or other commonly used equations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determining an accurate method to estimate GFR in renal transplant recipients with stable serum creatinine levels

Introduction:Detecting renal allograft dysfunction early will allow timely diagnosis and treatment. There is no objective recommendation by national kidney societies for glomerular filtration rate (eGFR) estimation in post-transplant setting. 99mTc-DTPA Technetium-99m Diethylene triamine penta acetic acid) renogram can identify early renal dysfunction much before ser...

متن کامل

Ultrasound-guided peripheral nerve blocks and intravascular injection.

method to estimate glomerular filtration rate from serum creatinine: A new prediction equation. Modification of Diet in Renal Disease Study Group. Ann Intern Med 1999; 130:461–70 6. Cockcroft DW, Gault MH: Prediction of creatinine clearance from serum creatinine. Nephron 1976; 16:31–41 7. Poggio ED, Wang X, Greene T, Van Lente F, Hall PM: Performance of the modification of diet in renal disease...

متن کامل

Comparison of bathophenanthroline sulfonate and ferene as chromogens in colorimetric measurement of low hepatic iron concentration.

Changes in plasma cystatin C after renal transplantation and acute rejection in adults. Clin Chem 1999;45:2243–9. 22. Le Bricon T, Thervet E, Froissart M, Benlakehal M, Bousquet B, Legendre C, Erlich D. Plasma cystatin C is superior to 24-h creatinine clearance and plasma creatinine for estimation of glomerular filtration rate 3 months after kidney transplantation [Letter]. Clin Chem 2000;46:12...

متن کامل

Accuracy and limitations of equations for predicting the glomerular filtration rate during follow-up of patients with non-diabetic nephropathies

Background Rapid and accurate estimation of the glomerular filtation rate (GFR) is required for many major clinical decisions in patients with chronic nephropathies [1]. Direct GFR measurement is time-consuming and expensive, frequently requires urine collection and isotope use, and is routinely available in only a few medical centers [1]. In clinical practice, GFR is usually estimated from the...

متن کامل

The glomerular filtration rate: comparison of various predictive equations based on serum creatinine with conventional creatinine clearance test in Pakistani population.

INTRODUCTION To compare the conventional creatinine clearance measured on 24-h urine collection with the estimated Glomerular Filtration Rate by Cockcroft & Gault (CG) and Modification of Diet in Renal Disease (MDRD) prediction equations in adults aged 20 years and above in Pakistani population. METHODS All the patients, including inpatient admitted in hospital and outpatients, more than 20 y...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of internal medicine

دوره 130 6  شماره 

صفحات  -

تاریخ انتشار 1999