Fluorescence of coumarins and xanthenes after two-photon absorption with a pulsed titanium-sapphire laser.

نویسندگان

  • A Fischer
  • C Cremer
  • E H Stelzer
چکیده

Fluorescence emission after two-photon absorption of coumarins and xanthenes in an alcoholic solution was measured in the tuning range of a femtosecond-pulsed titanium-sapphire laser (750-840 nm). Xanthenes, which have a low one-photon absorption in the near UV, show a higher fluorescence signal after two-photon absorption than the UV-excitable coumarins. When fluxes of 10(28) photons/(cm(2) s) are used, the two-photon absorption cross sections for xanthenes are 1 order of magnitude higher than the two-photon absorption cross sections of the coumarins. Absolute cross sections have been estimated for three coumarins and three xanthenes. For the xanthenes a significant wavelength-dependent departure from the expected fluorescence intensity square law was observed. The coumarins follow the square-law dependence. The consequences of the findings are discussed for analytic and diagnostic methods. An especially important result is that the resolution in two-photon microscopy of xanthenes is worse than expected.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

TWO PHOTON TRANSITIONS IN THE OPTOGALVANIC SPECTRUM OF NEON

Seventeen two-photon transitions for neon have been observed in the 580- 635 nm spectral region for use in the spectroscopic study of its higher excited levels, which are not accessible by one-photon absorption. To compare the two and one-photon absorption signals originating from the same lower level, an effort was made to record single-photon optogalvanic spectrum in the available wavele...

متن کامل

Two-Photon Fluorescence Excitation Cross Sections of Biomolecular Probes from 690 to 960 nm.

We report on two-photon fluorescence excitation (TPE) action cross sections for five widely used molecular fluorophores. Measurements were performed by use of ultrashort (~100-fs) Ti:sapphire pulsed excitation over the range 690-960 nm. TPE spectra were obtained by comparison with a fluorescein calibration standard. Large cross sections were found for the cyanine reagent Cy 3 (~140 GM) and for ...

متن کامل

A promising new wavelength region for three-photon fluorescence microscopy of live cells

We report three-photon laser scanning microscopy (3PLSM) using a bi-directional pumped optical parametric oscillator (OPO) with signal wavelength output at λ= 1500 nm. This novel laser was used to overcome the high optical loss in the infrared spectral region observed in laser scanning microscopes and objective lenses that renders them otherwise difficult to use for imaging. To test our system,...

متن کامل

Fluorescence Efficiency of Laser Dyes *

The recent development of the dye laser [1] 1 has opened up an important new field of applications for organic dyes. This has led to a renewed interest in the theory of nonradiative transitions in dyes and also to the synthesis of new highly fluores cent dyes. In this article we review briefly the relations between fluor· escence and molecular structure in the most important classes of laser dy...

متن کامل

Two-Photon Fluorescence Microscopy: Basic Principles, Advantages and Risks

The application of two-photon excitation to fluorescence microscopy has become a powerful tool for studying biological function in live tissue and offers many advantages over conventional imaging techniques. Neuroscientists in particular have used this technology to image physiological functioning in microscopic and subcellular neural compartments. Neurons can be imaged deep within highly light...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 34 12  شماره 

صفحات  -

تاریخ انتشار 1995