Assessment of Mitral Paravalvular Leakage After Mitral Valve Replacement Using Cardiac Computed Tomography: Comparison With Surgical Findings.

نویسندگان

  • Young Joo Suh
  • Geu-Ru Hong
  • Kyunghwa Han
  • Dong Jin Im
  • Suyon Chang
  • Yoo Jin Hong
  • Hye-Jeong Lee
  • Jin Hur
  • Byoung Wook Choi
  • Byung-Chul Chang
  • Chi Young Shim
  • Young Jin Kim
چکیده

BACKGROUND The diagnostic performance of cardiac computed tomography (CT) for detection of paravalvular leakage (PVL) after mitral valve replacement has not been investigated in a large population. We aimed to investigate the diagnostic accuracy of CT for diagnosis of mitral PVL using surgical findings as the standard reference and to compare the diagnostic performance of CT with those of transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE). METHODS AND RESULTS A total of 204 patients with previous mitral valve replacement who underwent cardiac CT were retrospectively included. The presence of mitral PVL was analyzed on CT, TTE, and TEE. In 78 patients who underwent redo-surgery, diagnostic performance for the detection of PVL for CT, TTE, and TEE were compared with surgical findings as the standard reference. The location of mitral PVL on CT and TEE was compared with surgical findings. Mitral PVL was present in 18.1% (37/204) on CT, in 16.2% (32/198) on TTE, and in 42.6% (29/68) on TEE. On the surgical field, PVL was identified in 41.0% (32/78). The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy for detection of PVL were 96.9%, 97.8%, 96.9%, 97.8%, and 97.4% for CT; 81.3%, 95.6%, 92.9%, 87.8%, and 89.6% for TTE; and 96.2%, 95.8%, 96.2%, 95.8%, and 96.0% for TEE. CT and TEE identified the correct location of PVL in 75.9% (22/29) and 85.6% (19/23). CONCLUSIONS Cardiac CT may have better diagnostic accuracy compared with TTE for the detection of mitral PVL and may be comparable to TEE for the detection and localization of PVL.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of Mitral Paravalvular Leakage After Mitral Valve Replacement Using Cardiac Computed Tomography

Paravalvular leakage (PVL) is uncommon but potentially serious complication after valve replacement, which occurs 7% to 17% after mitral valve replacement (MVR) and 2% to 10% after aortic valve replacement. Although most PVLs are asymptomatic and have a benign clinical course, an estimated 1% to 5% of patients with PVLs show serious clinical consequences, with especially more undesirable outcom...

متن کامل

AN INNOVATIVE SURGIC AL TECHNIQUE FOR CONTINUOUS SUTURING OF PROSTHESIS IN MITR AL VALVE REPL A CEMENT

Mitral valve replacement (MVR) is usually performed in two methods of running and interrupted suturing. In running method, the suturing of the valve is usually with some traction on the annulus and also there is a risk of aortic valve injury. This study was conducted to evaluate a new technique for suturing to avoid these complications and decrease the time of cardiac arrest. One hundred an...

متن کامل

Surgical Treatment of Rheumatic Mitral Valve Lesions in Children and Adolescents

Rheumatismal lesions of the mitral valve a!I'e rare under the age of six and surgical iruter­vention in symptomatic patients is an academic problem. Early surgical treatment has been done to prevent serious changes and unrevers­ib1e complications o.f the heart and lungs.  From April 71 until April 74, thirty-five pati­ent, ranging between 8-18 years of age, suffer­ing of <lifferents heart ,tro...

متن کامل

Unilateral pulmonary edema caused by paravalvular leakage recognized by bedside transesophageal echocardiography.

We describe a case of acute unilateral left pulmonary edema occuring in an old man one year after mitral valve replacement. Transesophageal echocardiography identified a paravalvular leakage with severe mitral regurgitant jet directed to both left pulmonary veins. A prompt surgical closure of the leakage by pericardial patch was decided with rapid clinical and radiological improvement.

متن کامل

Multiple paravalvular leak 17 years after a second mitral valve replacement

Paravalvular leak (PVL) after prosthetic valve implantation is a significant complication and it usually occurs early in the postoperative period. We report a case of multiple PVL 17 years after the second mitral valve replacement without evidence of infection. The valve sutures were neither cut nor loosened. None of the sewing cuff of the mitral valve was covered with fibrous tissue. The sewin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular imaging

دوره 9 6  شماره 

صفحات  -

تاریخ انتشار 2016