The Experimental plan of the 4m Resonant Sideband Extraction Prototype for The LCGT

نویسندگان

  • F. Kawazoe
  • K. Kokeyama
  • S. Sato
  • O. Miyakawa
  • K. Somiya
  • M. Fukushima
  • N. Arai
  • S. Kawamura
  • A. Sugamoto
چکیده

The 4m Resonant Sideband Extraction (RSE) interferometer is a planned prototype of the LCGT interferometer. The aim of the experiment is to operate a powerrecycled Broadband RSE interferometer with suspended optics and to achieve diagonalization of length signals of the central part of the interferometer directly through the optical setup. Details of the 4m RSE interferometer control method as well as the design of the experimental setup will be presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental investigation of a control scheme for a zero-detuning resonant sideband extraction interferometer for next-generation gravitational-wave detectors

Some next-generation gravitational-wave detectors, such as the American Advanced LIGO project and the Japanese LCGT project, plan to use power recycled resonant sideband extraction (RSE) interferometers for their interferometer’s optical configuration. A power recycled zero-detuning (PRZD) RSE interferometer, which is the default design for LCGT, has five main length degrees of freedom that nee...

متن کامل

Experimental investigation of a control scheme for a tuned resonant sideband extraction interferometer for next-generation gravitational-wave detectors

LCGT plans to use tuned RSE as the optical configuration for its interferometer. A tuned RSE interferometer has five degrees of freedom that need to be controlled in order to operate a gravitational-wave detector, although it is expected to be very challenging because of the complexity of its optical configuration. A new control scheme for a tuned RSE interferometer has been developed and teste...

متن کامل

Power-recycled Michelson interferometer with resonant sideband extraction.

We present a system for the control and signal extraction of a power-recycled Michelson interferometer with resonant sideband extraction. This control system is capable of locking four degrees of freedom to a fixed point while locking the signal cavity to an arbitrary detuned point. One of the strengths of this system is that it can quickly change the instrument's frequency response without dis...

متن کامل

Signal extraction and optical design for an advanced gravitational-wave interferometer.

We present an experimental demonstration of a locking and control scheme for an interferometer using a power-recycled resonant sideband extraction configuration and show that the measured response to mirror vibrations matches an optical model. We discuss some aspects of resonant sideband extraction that are relevant to gravitational-wave detection.

متن کامل

Experimental Study and steady state stability analysis of CLL-T Series Parallel Resonant Converter with Fuzzy controller using State Space Analysis

This paper presents a Closed Loop CLL-T (capacitor inductor inductor) Series Parallel Resonant Converter (SPRC) has been simulated and the performance is analysised. A three element CLL-T SPRC working under load independent operation (voltage type and current type load) is presented in this paper. The Steady state Stability Analysis of CLL-T SPRC has been developed using State Space technique a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006