High predictive value of red cell volume measurement using carboxy-haemoglobin in a rabbit model of haemorrhage.
نویسندگان
چکیده
We have studied the accuracy of blood volume measurements using carbon monoxide (CO)-labelled haemoglobin (COHb) injection and dilution (CO method) by comparing changes in red cell volume (RCV) measured using the CO method and 51Cr-labelled erythrocyte dilution (51Cr method) in a haemorrhage and infusion model in rabbits. RCV was measured repeatedly using the CO method at four different blood volume stages (stages I-IV). At stages I and IV, RCV was measured simultaneously using the 51Cr method. In comparing the sum of the circulating RCV and extracted RCV (SUM RCV) using the CO method, the values were almost equal and there were no significant differences between the values at the four stages. In comparing circulating RCV measured using the CO method and the 51Cr method, mean difference between the two methods was 0.80 (SD 0.76) ml kg-1 or 4.7 (4.6)%, and a positive correlation was observed (r = 0.91). We conclude that the CO method can be used to measure blood volume during perioperative periods in infants because it avoids use of a radioactive tracer, is simple and repeated measurements are possible.
منابع مشابه
Haematological Changes in Guinea Fowls (Numida meleagris galeata, Pallas) Following Haemorrhage
Haematological changes associated with haemorrhage were determined in the guinea fowl (Numida meleagris galeata, Pallas). The red blood cell, packed cell volume and mean corpuscular haemoglobin decreased significantly (p<0.05) at 4 h posthaemorrhage and returned to normalcy one week after hemorrhage. After 4 h of hemorrhage, the haemoglobin concentration also fell significantly (p<0.05). The fa...
متن کاملBathymetry and Volume Estimation of Reservoirs using OLI Imagary
Nowadays using field depth measurement to estimate capacity of water reservoirs is a costly and time consuming method. In this regard, different multiple techniques of remote sensing method has been adopted. In this study, a radiation and reflection based model was introduced to estimating the bathymetry and water capacity of reservoir by images of OLI sensor. For this, at May 17, 2015 water de...
متن کاملICSH recommendations for the measurement of haemoglobin F.
Measurement of the Haemoglobin F in red cell haemolysates is important in the diagnosis of δβ thalassaemia, hereditary persistence of fetal haemoglobin (HPFH) and in the diagnosis and management of sickle cell disease. The distribution of Hb F in red cells is useful in the diagnosis of HPFH and in the assessment of feto-maternal haemorrhage. The methods of quantifying Hb F are described togethe...
متن کاملBody Measurement of Red Sokoto Bucks in Nigeria and Their Relationship with Testicular Biometrics
Ninety Red Sokoto bucks were used to assess the relationship between body, testicular and epididymal measurements in three age groups (group 1: 7-12 months; group 2: between 1 and 2 years and group 3: older than 2 years). The effect of age on body and testicular / epididymal measurements was analyzed. A predictive model was developed for each of the testicular / epididymal measurements using li...
متن کاملPredictive value of red blood cell distribution width for mortality in patients with acute pancreatitis: A systematic review and meta-analysis
Background: Red blood cell distribution width (RDW) is a quantitative measure of variability in the size of circulating erythrocytes. It has been recently identified as a prognostic marker in several diseases including acute pancreatitis (AP). In this systematic review the prognostic value of RDW in predicting mortality of AP patients will be assessed. Methods: PubMed, Scopus, EMBASE, and ISI ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 81 6 شماره
صفحات -
تاریخ انتشار 1998