3D Dual VENC PCMRA using Spiral Projection Imaging
نویسنده
چکیده
Purpose: This work focuses on the reduction of scan time required by the phase-contrast (PC) MRA technique. The presented work builds on earlier work [1] in the way of parameter optimization. The proposed method consists of a 3D variable density spiral projection imaging (SPI) trajectory [2] combined with a dual velocity encoding technique [3]. SPI is a rapid imaging technique that improves acquisition time through the intrinsic efficiency of spirals and through undersampling. Spatial aliasing due to undersampling is minimized using a known iterative sampling density algorithm [4]. The dual-VENC method improves SNR by allowing low-VENC (high SNR) data to be reconstructed without phase aliasing of the velocity measurements. Methods: SPI: Undersampling in each spiral plane is achieved through variable density spiral interleaves (Figure 1(a)) which are collected with a critical sampling radius of about 1/8 the extent in k-space. Past this radius, the distance between spiral interleaves diverges from the Nyquist sampling distance by a linear rate until an undersampling of 4 is reached at the edge of k-space. Undersampling is also achieved by omitting planes. Planes are collected at even azimuthal distances, rotated around the kz axis (pole), providing a maximum undersampling of 4 at the edge (equator) of the sampled sphere (Figure 1(b)). The scan parameters for this sequence are as follows: 24cm FOV, 0.8mm voxel, 300 dia. matrix, 20 interleaves, 120 planes, 19.5msec TR, and a 6min total scan time for 7 volumes. Density Compensation: The MTF resulting from density compensation can be modulated to fit the density profile. Figure 1(c) is a plot of sample density along a radial projection in the equatorial plane. An MTF with this shape will lower the contribution (and therefore spatial aliasing) of undersampled spatial frequencies by the respective level of undersampling. Dual VENC: The velocity encoded sets were collected with a 100cm/s VENC and 20cm/s VENC in three directions each. In areas of high velocity gradients, such as vessel walls, the low-VENC data show higher signal loss causing vessels to appear narrow. To address this, a weighted combination of the high and low VENC data is used. Results and Discussion: Figure 1(d) and (e) are SPI PCMRA scans taken with a GE 3T Signa Excite system. There is susceptibility blurring near the sinus regions, which becomes problematic with even slightly longer sampling windows. Some smaller vessels appear spotted due aliasing caused by undersampling. Vessel diameter is regained by partial combination of high VENC data with the unaliased low VENC data. Conclusion: This method provides short scan times that make the added time required by the dual VENC techniques less prohibitive. The addition of parallel imaging is currently being explored for further reduction in scan time. References: 1: Koladia, ISMRM 06’, abs. 336; 2: Irarrazabal, MRM, 33:656, 1995; 3: Lee, MRM, 33:122, 1995; 4: Johnson, MRM, 61:439, 2009;
منابع مشابه
Accelerated Dual Velocity Encoded Phase Contrast VIPR
Introduction: Recently, several novel approaches for rapid MRI imaging have allowed for the acquisition of volumetric, time-resolved, phase contrast (PC) imaging with three-directional velocity encoding. One of these methods, PC vastly undersampled isotropic projection (PC VIPR) [1], a truly 3D radially undersampled acquisition, provides high resolution anatomical and velocity information in cl...
متن کاملAcclerated Dual Venc Phase Contrast VIPR in Healthy Volunteers
Introduction: Rapid imaging techniques now allow for the acquisition of volumetric, time-resolved, phase contrast (PC) images with three directional velocity encoding. Covering large vascular territories with a single 4D PC MRI makes choosing the proper velocity encoding (Venc) challenging. If the Venc is too low for a vessel of interest, velocity aliasing occurs. If chosen too high, the veloci...
متن کاملSimultaneous wall and blood-flow phase-contrast imaging using a single low VENC
Background Intra-ventricular blood flow and regional myocardial motion are two key components used in assessing cardiac function. Both can be quantified using phase contrast MRI, but typically require two imaging sequences to be acquired one with a high velocity encoding value (VENC) and one with a low VENC, selected to optimize velocity sensitivity while avoiding aliasing. In an effort to obta...
متن کاملBalanced MR Cholangiopancreatography with Motion-Sensitized Driven-Equilibrium (MSDE): Feasibility and Optimization of Imaging Parameter
Introduction In this study, a balanced steady-state free precession (SSFP) sequence with motion-sensitized driven-equilibrium (MSDE) was used as an alternative technique for MR cholangiopancreatography (MRCP). The anatomical evaluation of biliary system is a major objective of preoperative MRCP. Conventional T2-weighted MRCP at a high spatial resolution can visualize detailed pancreatobilialy a...
متن کاملProspective-triggered high-pitch spiral versus sequential dual-source CT coronary angiography: comparison of image quality and radiation dose
Background: Prospectively electrocardiography (ECG)-triggered high-pitch spiral coronary computed tomography angiography (CCTA) is a unique scan mode for dual-source CT (DSCT). Our reports aim to compare image quality and radiation dose of CCTA using high-pitch spiral or sequential acquisition mode in patients with low and stable heart rates. Materials and Methods: Patients with low and stable ...
متن کامل