A Frameless Stereotaxic MRI Technique for Macaque Neuroscience Studies

نویسندگان

  • David J Dubowitz
  • Miriam Scadeng
چکیده

MRI has achieved widespread use for preplanning neuroscience procedures for non-human primate studies. However, orienting imaging studies in stereotaxic space has relied primarily on using a stereotaxic frame or co-registering fiducial markers with the neuroimaging. In this study, we present a simple approach in which the MRI dataset is aligned to the bony landmarks that define the Frankfurt stereotaxic baseline plane, without the need for a stereotaxic frame or additional external fiducials. To facilitate localizing the bony landmarks (infraorbital margin, external bony auditory meatus) on the MRI scans additional imaging landmarks (mid ocular plane, temporomandibular joint) are discussed that provide supplementary and readily visible points of reference. The frameless MRI stereotaxic technique was evaluated in 8 rhesus macaque monkeys using 3D fast gradient echo MRI images with 0.7mm isotropic resolution. 1) Difference in stereotaxic coordinates of fiducial markers was compared between a traditional stereotaxic frame and the frameless MRI technique (n=2). 2) Differences in stereotaxic coordinates for cerebral regions were compared between the frameless MRI technique and MRI obtained with the animal positioned in a MRI-compatible stereotaxic frame (n=4). 3) The frameless MRI technique was further refined to prescribe electrode penetrations within a dural recording chamber in stereotaxic coordinates relative to the electrode microdrive. Differences in MRI coordinates were compared with the electrode microdrive (n=3). Mean localization of fiducial markers differed by 1.6 +/- 0.6 mm between the frameless MRI technique and a traditional stereotaxic frame. Between the frameless technique and an MRI-compatible stereotaxic frame, localization of cerebral anatomy differed by 2.8 +/- 2.2 mm with the primary source of error being a pitch-up rotation in the sagittal plane. This localization difference was reduced to 0.5 +/- 0.6 mm when this rotation was removed. Frameless MRI coordinates for electrode tracts within the dural recording chamber were within 0.5mm +/- 0.2 mm of the electrode microdrive readings. This simple technique provides the ability to accurately plan surgery and neurophysiological recordings in an individual animal, and to define the location of cerebral anatomy and electrode or injection tracts using publically available software, and without the need for dedicated MRI-compatible localization hardware. The reduced need for deep anesthesia (a necessity with traditional stereotaxic frames) makes the technique more amenable for functional MRI studies. Since each animal provides the bony landmarks to define their own stereotaxic space, this technique is readily applicable to other species.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The advantages of frameless stereotactic biopsy over frame-based biopsy.

A comparison study is presented, which examines the outcome, complications and cost of stereotactic brain biopsy performed with a frameless versus a frame-based method. The technique of frameless stereotactic biopsy has been shown previously, in both laboratory and in vivo studies, to achieve a level of accuracy at least equal to frame-based biopsy. The investigators have validated the techniqu...

متن کامل

Towards localization of transcranial magnetic stimulation inside the MRI scanner

Background and Motivations: Transcranial magnetic stimulation (TMS) has been used as a non-invasive tool in various neuroscience applications including investigating brain functions, serving as a clinical diagnostic tool and as a therapy for several neuropsychiatric disorders [1]. TMS delivers time-pulse magnetic fields created by special coils to induce local currents in the tissue i.e., neuro...

متن کامل

The Effect of Electrical Fields from High-Voltage Transmission Line on Cognitive Changes in Male Rhesus Macaque Monkeys: A Biological and Anatomical Study Using MRI Case Report Study

Living near high-voltage power lines and exposure to high-frequency electromagnetic fields (EMFs) is a potential serious hazard to animal and human health. The present study was carried out to evaluate the effect of high-frequency EMFs from simulated high-voltage electric towers on cognitive, anatomical, and biological changes in male Macaque. In this study, two Rhesus Macaque were recruited, ...

متن کامل

Correlation of the CT Compatible Stereotaxic Craniotomy with MRI Scans of the Patients for Removing Cranial Lesions Located Eloquent Areas and Deep Sites of Brain

The first goal in neurosurgery is to protect neural function as long as it is possible. Moreover, while protecting the neural function, a neurosurgeon should extract the maximum amount of tumoral tissue from the tumour region of the brain. So neurosurgery and technological advancement go hand in hand to realize this goal. Using of CT compatible stereotaxy for removing a cranial tumour is to be ...

متن کامل

The effect of 12 Hz Extremely Low-Frequency Electromagnetic Fields on Visual Memory of Male Macaque Monkeys

Introduction: Today, humans leave in a world surrounded by electromagnetic fields. Numerous studies have been carried out to discover the biological, physiological, and behavioral effects of electromagnetic fields on humans and animals. Given the biological similarities between monkeys and humans, the goal of the present research was to examine Visual Memory (VM), hormonal, genomic, and anatomi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2011