Effect of endocervical specimen adequacy on ligase chain reaction detection of Chlamydia trachomatis.

نویسندگان

  • M J Loeffelholz
  • S J Jirsa
  • R K Teske
  • J N Woods
چکیده

Several studies have demonstrated that the sensitivity of a commercially available PCR test for the detection of Chlamydia trachomatis (Roche Diagnostics) is affected by the cellular quality of the endocervical swab specimens. The cellular adequacies of 1,633 female endocervical swab specimens were assessed and compared with the results of C. trachomatis detection obtained by ligase chain reaction (LCR; Abbott Laboratories). Specimen adequacy studies and LCR were performed with samples from the same swab, after demonstration of the stability of human epithelial cells in LCR transport medium. Prior to heat treatment of the swab specimen, an aliquot was removed and cytocentrifuged onto a slide. Cell spots were stained and examined at x 400 magnification for endocervical (columnar epithelial or metaplastic) cells and erythrocytes. The overall rate of positivity of the LCR was 6.5% (106 of 1,633 specimens) with pooled specimens (pools of 4 specimens each; reduced cutoff). Of the 1,633 specimens examined, 655 (40.1%) were found to contain one or more endocervical cells. The rate of positivity for C. trachomatis was 10.8% (71 of 655 specimens) among specimens containing endocervical cells, whereas it was 3.6% (35 of 978 specimens) among specimens lacking endocervical cells (P < 0.0001). There was no linear trend between the rate of positivity for C. trachomatis and the number of endocervical cells (P = 0.24). The rate of positivity for C. trachomatis was 5.4% (8 of 147 specimens) among specimens containing large numbers of erythrocytes (> or =100 per high-power field), whereas it was 6.6% (98 of 1,486 specimens) among specimens containing less than 100 erythrocytes per high-power field (P = 0.59). These results show that the sensitivity of the Abbott C. trachomatis LCR test is affected by the presence of endocervical cells. Additionally, they indicate that the presence of a single endocervical cell is as good an indicator of specimen adequacy as the presence of many endocervical cells. The presence of a large number of erythrocytes was not associated with an increased rate of sensitivity of the LCR.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of endocervical-specimen adequacy on detection of Chlamydia trachomatis by the APTIMA COMBO 2 assay.

Six hundred one endocervical specimens were analyzed for Chlamydia trachomatis by the APTIMA Combo 2 assay and evaluated for columnar epithelial cell adequacy by direct fluorescent-antibody staining. With 5.5% positive adequate and 7.8% positive inadequate specimens (P=0.27), the study suggested no difference in positivity rates due to specimen adequacy when this amplified technology was used.

متن کامل

Comparison of a polymer conjugate-enhanced enzyme immunoassay to ligase chain reaction for diagnosis of Chlamydia trachomatis in endocervical swabs.

Two endocervical swabs from each of 1,123 women were collected into manufacturer-supplied transport tubes and tested for Chlamydia trachomatis by a polymer conjugate-enhanced (PCE) enzyme immunoassay (EIA) (IDEIA PCE Chlamydia; DAKO) and a ligase chain reaction assay (LCx Chlamydia; Abbott). After confirmation by the EIA blocking test, the sensitivity of the IDEIA PCE remained at 91.8% and the ...

متن کامل

Assessment of Chlamydia trachomatis prevalence by PCR and LCR in women presenting for termination of pregnancy.

OBJECTIVES To determine the prevalence of Chlamydia trachomatis in a patient population presenting for legal termination of pregnancy by polymerase chain reaction (PCR) and ligase chain reaction (LCR), from first catch urine and self administered tampons, and comparing with the traditionally collected endocervical swab tested by both PCR and culture. METHODS Consecutive women attending for le...

متن کامل

A comparison of ligase chain reaction to polymerase chain reaction in the detection of Chlamydia trachomatis endocervical infections.

OBJECTIVE To compare the reliability of ligase chain reaction (LCR) to polymerase chain reaction (PCR) in detecting Chlamydia trachomatis endocervical infections. METHODS We conducted a prospective study of 486 patients at risk for chlamydial infection of the endocervix. We obtained two endocervical specimens from each patient and used LCR and PCR to detect C. trachomatis. Discrepant results ...

متن کامل

Comparison of performances of two commercially available tests, a PCR assay and a ligase chain reaction test, in detection of urogenital Chlamydia trachomatis infection.

The diagnostic performance of a PCR test (Roche Cobas Amplicor CT/NG Test) and that of a ligase chain reaction (LCR) test (Abbott LCx Chlamydia trachomatis assay) were compared by using endocervical and urethral swab specimen culture as a reference test. First-void urine (FVU) and endocervical and urethral swab specimens were collected from 1,015 unselected patients attending a sexually transmi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 39 11  شماره 

صفحات  -

تاریخ انتشار 2001