Multiplexed rectilinear ion trap mass spectrometer for high-throughput analysis.

نویسندگان

  • Amy M Tabert
  • Michael P Goodwin
  • Jason S Duncan
  • Charles D Fico
  • R Graham Cooks
چکیده

A multichannel mass spectrometer based on the rectilinear ion trap (RIT) analyzer was designed and constructed for simultaneous high-throughput analysis of multiple samples. The instrument features four parallel ion source/mass analyzer/detector channels assembled in a single vacuum chamber and operated using a common set of control electronics, including a single rf amplifier and transformer coil. This multiplexed RIT mass spectrometer employs an array of four millimeter-sized ion traps (x(o) = 5.0 mm and y(o) = 4.0 mm, where x(o) and y(o) are the half-distances in the x and y dimensions, respectively). Mass spectra are acquired from four different samples simultaneously. The available mass/charge range is m/z 15-510 with excellent linearity of the mass calibration (R2 = 0.999 999). The peak width is less than 0.3 mass/charge units at m/z 146, corresponding to a resolution of approximately 500. Simultaneous MS/MS of ions due to four compounds (3-fluoroanisole, 4-fluoroanisole, 2-fluorobenzyl alcohol, 2,6-dimethylcyclohexanone) with the same nominal molecular radical cation but distinctive fragmentation patterns was demonstrated. Isolation and fragmentation efficiencies were approximately 25 and approximately 75%, respectively, measured in the typical case of the molecular radical cation of acetophenone. Preacquisition differential data were obtained by real-time subtraction of the ion signals from two channels of the multiplexed mass spectrometer. The differential experiment presented offers proof of principle of comparative mass spectra in high-throughput screening applications while reducing data storage requirements.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SHORT COMMUNICATION Co-occurrence of Boundary and Resonance Ejection in a Multiplexed Rectilinear Ion Trap Mass Spectrometer

A method is reported for evaluating ion trap mass analyzers by selection of operating conditions under which both boundary and resonance ejection peaks occur in a single mass scan. The choice of frequency and amplitude of the auxiliary waveform applied for resonance ejection can be such as to produce a resonance ejection mass spectrum with unit resolution or, under selected conditions, signals ...

متن کامل

Co-occurrence of boundary and resonance ejection in a multiplexed rectilinear ion trap mass spectrometer.

A method is reported for evaluating ion trap mass analyzers by selection of operating conditions under which both boundary and resonance ejection peaks occur in a single mass scan. The choice of frequency and amplitude of the auxiliary waveform applied for resonance ejection can be such as to produce a resonance ejection mass spectrum with unit resolution or, under selected conditions, signals ...

متن کامل

Quadrupole ion traps and trap arrays: geometry, material, scale, performance.

Quadrupole ion traps are reviewed, emphasizing recent developments, especially the investigation of new geometries, guided by multiple particle simulations such as the ITSIM program. These geometries include linear ion traps (LITs) and the simplified rectilinear ion trap (RIT). Various methods of fabrication are described, including the use of rapid prototyping apparatus (RPA), in which 3D obje...

متن کامل

Dual-pressure linear ion trap mass spectrometer improving the analysis of complex protein mixtures.

The considerable progress in high-throughput proteomics analysis via liquid chromatography-electrospray ionization-tandem mass spectrometry over the past decade has been fueled to a large degree by continuous improvements in instrumentation. High-throughput identification experiments are based on peptide sequencing and are largely accomplished through the use of tandem mass spectrometry, with i...

متن کامل

Profiling and Characterization of Polyphenol Polymers from Cinnamon Using an Ion Trap Mass Spectrometer

Type 2 diabetes is the most common metabolic disease worldwide. Although the prevention and control of it remains unclear, there is strong evidence that dietary factors play a role in the onset of this disease. Previous studies have indicated that cinnamon may mimic insulin effects and thus may improve glucose uptake.1–2 Considering the complex composition of cinnamon, it is important to be abl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 78 14  شماره 

صفحات  -

تاریخ انتشار 2006