Evaluation of the interfractional biological effective dose (BED) variation in MammoSite high dose rate brachytherapy
نویسندگان
چکیده
The objective of this work is to evaluate the interfractional biological effective dose (BED) variation in MammoSite high dose rate (HDR) brachytherapy. Dose distributions of 19 patients who received 34 Gy in 10 fractions were evaluated. A method was employed to account for nonuniform dose distribution in the BED calculation. Furthermore, a range of alpha/beta values was utilized for specific clinical end points: fibrosis, telangiectasia, erythema, desquamation and breast carcinoma. Two scenarios were simulated to calculate the BED value using: i) the same dose distribution of fraction 1 over fractions 2-10 (constant case, CC), and ii) the actual delivered dose distribution for each fraction 1-10 (interfractiondose variation case, IVC). Although the average BED difference (IVC - CC) was < 0.7 Gy for all clinical endpoints, the range of difference for fibrosis and telangiectasia reached -11% to +3% and -9% to +9% for one of the patients, respectively. By disregarding high inhomogeneity in HDR brachytherapy, the conventional BED calculation tends to overestimate the BED for fibrosis by 16% on average, while it underestimates the BED for erythema (7.6%) and desquamation (10.2%). In conclusion, the BED calculation accounting for the nonuniform dose distribution provides a more clinically relevant description of the clinical delivered dose. Though the average BED difference was clinically insignificant, the maximum difference of BED for late effects can differ by a single fractional dose (10%) for a specific patient due to the interfraction dose variation in MammoSite treatment.
منابع مشابه
Proof of Symmetric Dose Distribution in Mammosite Applicator in Breast Brachytherapy with MCNP Simulation
Introduction: In brachytherapy treatments, high-dose sources are used in interstitial placement. In this paper, the modeling of a common breast cancer treatment applicator called MammoSite is done by the Monte Carlo simulation code. Then, to study and calculate the amount of doses in the breast and the dose rate of the organs at risk of radiation, including: lungs, ribs and ski...
متن کاملCalculation of absorbed dose rate in the lungs, ribs and skin by the mammosite applicator in breast cancer brachytherapy with MCNP
Introduction: Breast cancer is the most common cancer among women. Brachytherapy is one of the ways to treat breast cancer. In brachytherapy treatments, high-dose sources are used in interstitial placement. Here, Iridium-192 is used. This source emits gamma rays with energies ranging from 136 kV to 1060 kV electron volts. The activity of the used spring is 10 Ci. The simulated ...
متن کاملA Comparison of Skin Dose Delivered with MammoSite and Multicatheter Breast Brachytherapy
Background: Accelerated partial breast irradiation via interstitial balloon brachytherapy is a fast and effective treatment method for certain early stage breast cancers however skin, chest wall and Lung doses are correlated with toxicity in patients treated with breast brachytherapy.Objective: To investigate the percentage of the dose received by critical organ (skin), thermoluminescence detec...
متن کاملThe impact of uncertainties associated with MammoSite brachytherapy on the dose distribution in the breast
The MammoSite radiation therapy system is a novel technique for treatment of patients with early-stage breast cancer. It was developed to overcome the longer schedules associated with external-beam radiation therapy. It consists of a small balloon (4 cm in diameter) connected to an inflation channel and a catheter for the passage of a high dose rate 192Ir brachytherapy source. The device is pla...
متن کاملQuantitative evaluation of the dosimetric effects of balloon deformation and source position in high-dose rate mammosite breast brachytherapy.
PURPOSE To investigate quantitatively the deformation of the mammosite balloon, eccentricity of the source position and their effects on the dose delivered to the tumor lumpectomy site and critical structures. MATERIALS AND METHODS The distances of the brachytherapy source to the surface of the mammosite balloon were measured in using radiographic images for fractions 1 to 10 for twelve patie...