X-ray detectors for digital radiography.
نویسندگان
چکیده
Digital radiography offers the potential of improved image quality as well as providing opportunities for advances in medical image management, computer-aided diagnosis and teleradiology. Image quality is intimately linked to the precise and accurate acquisition of information from the x-ray beam transmitted by the patient, i.e. to the performance of the x-ray detector. Detectors for digital radiography must meet the needs of the specific radiological procedure where they will be used. Key parameters are spatial resolution, uniformity of response, contrast sensitivity, dynamic range, acquisition speed and frame rate. The underlying physical considerations defining the performance of x-ray detectors for radiography will be reviewed. Some of the more promising existing and experimental detector technologies which may be suitable for digital radiography will be considered. Devices that can be employed in full-area detectors and also those more appropriate for scanning x-ray systems will be discussed. These include various approaches based on phosphor x-ray converters, where light quanta are produced as an intermediate stage, as well as direct x-ray-to-charge conversion materials such as zinc cadmium telluride, amorphous selenium and crystalline silicon.
منابع مشابه
Quality comparison of direct digital panoramic radiography and computed radiography panoramic
BACKGROUND AND AIM: Digital panoramic X-ray images can be captured using photostimulable phosphors or solid-state detectors (i.e. charge-coupled devices and Flat-Panels). The first category is defined as computed radiography (CR) or semi-direct radiography. The second technology that uses solid-state detectors is known as direct digital radiography (DDR). Both of these technologies have their o...
متن کاملPatient effective dose evaluation for chest X-ray examination in three digital radiography centers
Background: The radiation doses resulting from diagnostic X-ray examinations are routinely measured in terms of entrance surface dose (ESD) and effective dose (ED). In this study, for the purpose of radiation protection, the radiation doses received from Digital chest X-ray examination were evaluated in terms of ESD and ED. Material and Methods: The ED was calculated by using the MCNP ...
متن کاملEvaluation of New Digital Detectors for High Resolution Radiography
Abstract: In the actual study, two digital detectors were investigated : an amorphous silicon flat panel and a TDI multilinear detector. The contrast and IQI sensitivity was selected to compare flat panel and film radiography. The influence of X-ray conditions was assessed in the case of flat panel. Spatial resolution of both digital detectors was assessed by adapting the geometrical magnificat...
متن کاملReplacement of Film Radiography by Digital Techniques and Enhancement of Image Quality
New digital detectors were developed for medical applications, which have the potential to substitute the X-ray film. Digital Detector Arrays (DDA: Flat Panel Detectors, Line Detectors) and Imaging Plates (Computed Radiography, CR) allow a fast acquisition of radiographic images with higher dynamic than film. Especially DDA’s allow a radiographic inspection with considerable higher image qualit...
متن کاملPaediatric Dose AssessmentToward Establishment of National Diagnostic Reference Levels for Digital Radiography Examinations in Iran
Introduction: Paediatric patients deserve special attention because of the higher radiation risks compared with adults. The main purpose of this study is to determine patient dose and diagnostic reference level for Paediatric through Entrance Surface Dose (ESD) calculations in common X-ray examination and to establish Paediatric national DRLs in digital radiography in Iran. <...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 42 1 شماره
صفحات -
تاریخ انتشار 1997