Flow injection analysis-solid phase extraction (FIA-SPE) method for preconcentration and determination of trace amounts of penicillins using methylene blue grafted polyurethane foam.

نویسندگان

  • M F El-Shahat
  • N Burham
  • S M Abdel Azeem
چکیده

A simple, fast, and fully automated FIA-SPE method with UV detection for the preconcentration and determination of the investigated penicillins has been developed. This paper provides adequate procedure for the preconcentration and determination of the studied compounds in pharmaceuticals and milk samples. Penicillins (penicillin G, amoxicillin, and ampicillin) are extracted in a mincolumn packed with methylene blue grafted polyurethane foam (MBGPUF) material. The antibiotics are eluted by hydrochloric acid solution to the flow cell of UV-vis spectrophotometer at 230 nm. The analytes are preconcentrated on the sorbent at pH 8.0-9.5 and sample flow rate 3.0 mL/min. Elution was performed with 200 microL 0.2 mol L(-1) hydrochloric acid at 2 mL min(-1). Sample throughput is 12h(-1) at 120 s preconcentration time. High selectivity of the sorbent for the analytes was achieved at the specified pH range. The enrichment factors achieved are 14, 16, and 11 with 3 sigma detection limits of 12, 15, and 19 ng mL(-1) for penicillin G, amoxicillin and ampicillin, respectively. The method was successfully applied to the determination of these antibiotics in pharmaceutical control and contaminated milk samples with RSD<or=8.8%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Solid Phase Extraction of Amount Cu(II) Using C18 Disks Modified Schiff Base-Chitosan Grafted Multiwalled Carbon Nanotubes

A novel and selective method for the fast determination of trace amounts of Cu(II) ions in water samples has been developed. The procedure is based on the selective formation of Cu(II) at optimum pH by elution with organic eluents and determination by flame atomic absorption spectrometry. The method is based on complex formation on the surface of the ENVI-18 DISKTM disks modified Schiff base-ch...

متن کامل

Solid Phase Extraction of Amount Cu(II) Using C18 Disks Modified Schiff Base-Chitosan Grafted Multiwalled Carbon Nanotubes

A novel and selective method for the fast determination of trace amounts of Cu(II) ions in water samples has been developed. The procedure is based on the selective formation of Cu(II) at optimum pH by elution with organic eluents and determination by flame atomic absorption spectrometry. The method is based on complex formation on the surface of the ENVI-18 DISKTM disks modified Schiff base-ch...

متن کامل

Review of preconcentration and solid phase extraction for the determination of trace Lead

Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...

متن کامل

Review of preconcentration and solid phase extraction for the determination of trace Lead

Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...

متن کامل

Solid-phase Extraction Using Modified Carbon Nanotube and Cupferron Ligand for Preconcentration and Determination of Trace Amounts of Copper in Real Samples

A solid phase extraction procedure for simultaneous separation and preconcentration of traceamounts of Cu+2 ion from various real samples prior to its determination by flame atomicabsorption spectrometry has been developed. The proposed method is based on the utilization ofmultiwalled carbon nanotube in combination with Cupferron ligand as a solid phaseextractant. The influences of the analytic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of hazardous materials

دوره 177 1-3  شماره 

صفحات  -

تاریخ انتشار 2010