AutoLock: a semiautomated system for radiotherapy treatment plan quality control
نویسندگان
چکیده
A semiautomated system for radiotherapy treatment plan quality control (QC), named AutoLock, is presented. AutoLock is designed to augment treatment plan QC by automatically checking aspects of treatment plans that are well suited to computational evaluation, whilst summarizing more subjective aspects in the form of a checklist. The treatment plan must pass all automated checks and all checklist items must be acknowledged by the planner as correct before the plan is finalized. Thus AutoLock uniquely integrates automated treatment plan QC, an electronic checklist, and plan finalization. In addition to reducing the potential for the propagation of errors, the integration of AutoLock into the plan finalization workflow has improved efficiency at our center. Detailed audit data are presented, demonstrating that the treatment plan QC rejection rate fell by around a third following the clinical introduction of AutoLock.
منابع مشابه
Improving the efficiency of breast radiotherapy treatment planning using a semi‐automated approach
OBJECTIVES To reduce treatment planning times while maintaining plan quality through the introduction of semi-automated planning techniques for breast radiotherapy. METHODS Automatic critical structure delineation was examined using the Smart Probabilistic Image Contouring Engine (SPICE) commercial autosegmentation software (Philips Radiation Oncology Systems, Fitchburg, WI) for a cohort of t...
متن کاملAssessment of two different dose distribution algorithms (Clarkson and Superposition) in PCRT3D treatment planning system for Esophagus Cancer by using 3DCRT technique
Introduction: The functionality and quality of any treatment planning system (TPS) strongly depends on the type of Algorithm which is used by it. Obviously, the role of dose distribution algorithms in calculation of prescribed dose inside the tumor in modern radiotherapy techniques has more important than past to achieve the best clinical outcomes, especially in tumors which ar...
متن کاملFewer beams and segments result in a shorter delivery time and a better quality intensity-modulated radiotherapy plan in gastric cancer
Background: This study evaluated whether IMRT using fewer beams and segments could reduce delivery time without compromising plan quality in gastric cancer adjuvant radiotherapy. Materials and Methods: Fifteen patients with advanced gastric cancer who underwent D2, R0 surgery were included in this study. IMRT plans for each patient were designed as 7 equal beams with 40 segments, 5 beams with 2...
متن کاملComparison and evaluation of dosimetric and radiobiological parameters in two different treatment plans in stomach cancer by use of 3D CRT
Introduction: In 3DCRT the number of therapeutic fields has dramatic impact on treatment results especially in stomach cancer. Traditionally, for radiotherapy of stomach cancer the therapeutic procedure was using two fields (AP- PA or AP Lateral with wedge) to achieve smooth and homogeneous dose distribution in tumor. But nowadays, adding lateral or oblique fields to aforement...
متن کامل2D linear array device as a quality assurance tool in brachytherapy applications
Background: External beam radiotherapy and brachytherapy plays a vital role in the management of cancer cervix. High dose rate brachytherapy is being presently used worldwide for the brachytherapy applications. At present, 2-Dimensional linear array detectors are the most common QA tool used for pretreatment patient specific quality assurance in external beam radiotherapy alon...
متن کامل