Assessment of the Cobas Bio centrifugal analyser

نویسندگان

  • Renze Bais
  • Robyn G. White
  • Donald Elston
  • Terence D. Geary
چکیده

The Cobas Bio (Roche) is a discrete spectrometric centrifugal analyser which is capable of monitoring :29 reaction cuvettes. The dispensing and analysing systems are contained within one unit and an Intel 8080A microprocessor controls the total system. Two Hamilton syringes are used to pipette samples and reagents. The sample and reagent syringes have nominal capacities of 100 and 400 #1 respectively. A second reagent can be pipetted by the sample syringe at a time interval of between 10 and 999 s. Up to 25 sample cups are housed in coded discs which form the basis ofan identification system. The sample cups are capped to minimize evaporation. They can be placed in one of two positions and the probe will only sample, by piercing the cup, those cups which are in the down position. This provides a way of selectively running different methods on the same sample plate. The reagent boat contains receptacles for the primary and secondary reagents and up to three standards. The reagent pipettor uses disposable plastic tips, whereas the stainless-steel tip of the sample pipettor is automatically rinsed between samples. The disposable rotor constructed from acrylic butadiene styrene polymer has 30 cuvettes, one ofwhich is used to optimize the photometer light-source characteristics. A program allows for the effective use ofempty cuvettes and the rotor need only be removed when all the cuvettes have been used. Ifthe photometer arm is raised or the instrument turned off, this program is reset and the rotor must be replaced. The detector unit consists of a digitally-controlled concave halographic grating monochromator, a central processing unit controlled energy adjustment system and a photodiode detector. The pulsed Xenon flash-tube has a spectral range of285-750 nm. Unlike other centrifugal analysers, the optical path-length is not fixed as the Cobas Bio measures absorbance in the same direction as the centrifugal force (see figure 1). The calculation factor is therefore dependent only on the selected sample volume and not the ratio of sample to reagent volume (Eisenwiener and Keller [l-l). This allows the addition ofa second reagent without altering the calculation factor (Eisenwiener et al. [2]). Space is available for 30 programs, 10 have a key specifically

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immunoturbidimetric assays for serum apolipoproteins A1 and B using Cobas Bio centrifugal analyser.

Immunoturbidimetric assays for measuring the apolipoproteins A1 and B using the Cobas Bio centrifugal analyser are described. The methods were specific, offered good sensitivity (less than 0.05 g/l) and intrabatch variability, with coefficients of variation between 2.4% and 3.5%, and were cost effective. Reference ranges were calculated for a group of civil servants, aged 35 to 55 years.

متن کامل

Determination of free haemoglobin in serum by an automated assay using 4-aminophenazone and the Cobas Bio System.

A colorimetric method for the determination of free haemoglobin in human serum is described, using 4-aminophenazone as chromogen, and commercially available haemiglobin cyanide solutions as standards. The reaction system is suitable for manual measurements as well as determinations with a centrifugal analyser (Cobas Bio System). Accuracy, linearity and stability of the procedure is shown. A ref...

متن کامل

Adaptation of methods for glutamate dehydrogenase and alcohol dehydrogenase activities to a centrifugal analyser: assessment of their clinical use in anoxic states of the liver.

Sensitive, precise, and rapid methods for the measurement of alcohol dehydrogenase (ADH) and glutamate dehydrogenase (GDH) were developed on the Cobas Bio centrifugal analyser. The optimal pH for ADH in caucasians was 9.8. Non-linearity of ADH enzyme activity was observed when samples were diluted in saline; linearity was restored when inactivated serum was used as diluent. ADH was shown to be ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of Automatic Chemistry

دوره 4  شماره 

صفحات  -

تاریخ انتشار 1982