Device Conformability and Morphological Assessment After TEVAR for Aortic Type B Dissection: A Single-Centre Experience with a Conformable Thoracic Stent-Graft Design

نویسندگان

  • Moritz S. Bischoff
  • Matthias Müller-Eschner
  • Katrin Meisenbacher
  • Andreas S. Peters
  • Dittmar Böckler
چکیده

BACKGROUND The aim of this study was to analyze device conformability in TEVAR of acute and chronic (a/c) type B aortic dissections (TBAD) using the Gore Conformable Thoracic Aortic Stent-graft (CTAG). MATERIAL AND METHODS From January 1997 to February 2014, a total of 90 out of 405 patients in our center received TEVAR for TBAD. Since November 2009, 23 patients (16 men; median age: 62 years) were treated with the CTAG. Indications were complicated aTBAD in 15 (65%) and expanding cTBAD in 8 (35%) patients. Primary endpoints were the assessment of device conformability by measuring the distance (D) from the radiopaque gold band marker (GM) at the proximal CTAG end to the inner curvature (IC) of the arch on parasagittal multiplanar reformations of CT angiography, as well as the evaluation of aortic diameter changes following TEVAR. Median follow-up was 13.3 months (range: 2 days to 35 months). RESULTS Primary and secondary success rates were 91.3% (21/23) and 95.6% (22/23), respectively. There was 1 type Ia endoleak, retrograde dissection or primary conversion was not observed. Median GM-IC-D was 0 mm (range: 0 mm to 10 mm). GM-IC-D was associated with zone 2 placement compared to zone 3 (P=0.036). There was no association between GM-IC-D formation and arch type. In aTBAD cases the true lumen significantly increased after TEVAR (P=0.017) and the false lumen underwent shrinkage (P=0.025). In cTBAD patients the false lumen decreased after TEVAR (P=0.036). CONCLUSIONS The CTAG shows favorable conformability and wall apposition in challenging arch pathologies such as TBAD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contemporary Role of Computational Analysis in Endovascular Treatment for Thoracic Aortic Disease.

In the past decade, thoracic endovascular aortic repair (TEVAR) has become the primary treatment option in descending aneurysm and dissection. The clinical outcome of this minimally invasive technique is strictly related to an appropriate patient/stent graft selection, hemodynamic interactions, and operator skills. In this context, a quantitative assessment of the biomechanical stress induced i...

متن کامل

Emergency thoracic aortic stent grafting for acute complicated type B aortic dissection after a previous abdominal endovascular aneurysm repair

We report a case of acute type B aortic dissection with the complication of bowel ischemia and abdominal stent graft compression treated by emergency thoracic aortic stent grafting after endovascular aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA). A 69-year-old male was admitted to our hospital for sudden thoraco-abdominal pain. He had past treatment history of EVAR for AAA half a y...

متن کامل

Two Cases of Endovascular Repair with the Stent Graft for Retrograde Type A Acute Aortic Dissection with Complications.

Thoracic endovascular aortic repair (TEVAR) is used to treat retrograde type A acute aortic dissection (RTAAD). In case 1, a 52-year-old man, who was conservatively managed, reported worsening back pain. Emergency TEVAR was performed 7 days after onset. After deploying two GORE Conformable TAG (CTAG) in the descending aorta, his symptoms disappeared. In case 2, a 52-year-old man with progressiv...

متن کامل

Implication of thoracic aortic stent-graft conformability on clinical outcomes.

Endovascular management concepts have recently emerged as valuable treatment options for both simple and complex disorders involving both the distal arch and descending thoracic aorta. With growing use of endovascular stent-grafts the technique has generated broad interest. Nevertheless, an ideal device for different thoracic aortic conditions is not available yet. After initially using the fir...

متن کامل

Restrictive bare stent for prevention of stent graft-induced distal redissection after thoracic endovascular aortic repair for type B aortic dissection.

BACKGROUND Stent graft-induced distal redissection (SIDR) is one of the major concerns in the durability of endovascular repair for complicated Stanford type B aortic dissection. The characteristics and means of prevention of this complication remain unknown. METHODS From April 1997 to March 2010, 674 patients with type B aortic dissections were treated primarily by thoracic endovascular aort...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 21  شماره 

صفحات  -

تاریخ انتشار 2015