Accuracy of non - invasive intracranial pressure measurement
نویسندگان
چکیده
Non-invasive measurement of intracranial pressure (ICP) reduces the complications and cost for both patient and health care systems. Improvement of non-invasive methods has led to development of systems for reproducing continuous, real-time non-invasive ICP signals. So far, non-invasive methods have been tailored for the patients with head trauma. We have used Schmidt’s auto-adaptive method to assess the accuracy of this method for patients after surgery for supratentorial brain tumors. Data from forty patients with the diagnosis of brain tumor operated from 2008 to 2010 were used to estimate the accuracy of Schmidt’s method in our patients. We obtained the model parameters from 30 recordings. We determined the ICP wave form for the remaining patients by both invasive and non-invasive techniques. In the test group, by invasive method, the mean ICP± 2SD was 17.1 ± 6.6 mmHg and using non-invasive method, the mean ICP ± 2SD was 16.5 ± 5.4 mmHg. The calculated error was 4.6 mmHg using root mean square errors. The average Pearson correlation between the estimated and real waveforms was 0.92. We believe that application of this method is acceptable for post-operative assessment of ICP in brain tumor patients. © Versita Sp. z o.o.
منابع مشابه
Investigation of intracranial media ultrasonic monitoring model.
The objectives are to investigate the peculiarities of the ultrasound pulse propagation through human extra/intracranial media by mathematical simulation and to confirm the simulation results experimentally by proving the suitability of the ultrasonic time-of-flight measurement method for human intracranial media (IM) physiological non-invasive monitoring. The mathematical model of ultrasound p...
متن کاملMeasurement of fontanelle pressure (Part I). A new instrument for non-invasive measurement of intracranial pressure via the anterior fontanelle.
Intracranial pressure (ICP) is one of the most important parameters for evaluating intracranial conditons. The skulls of newborns and infants, unlike the tightly sutured skull of adults, provide non-invasive access for measurement of ICPs via the anterior fontanelle. A new transducer has been developed which is convenient for non-invasive, continuous measurement of intracranial pressure through...
متن کاملIntracranial Pressure Monitoring: Invasive versus Non-Invasive Methods—A Review
Monitoring of intracranial pressure (ICP) has been used for decades in the fields of neurosurgery and neurology. There are multiple techniques: invasive as well as noninvasive. This paper aims to provide an overview of the advantages and disadvantages of the most common and well-known methods as well as assess whether noninvasive techniques (transcranial Doppler, tympanic membrane displacement,...
متن کاملClinical comparison of tympanic membrane displacement with invasive intracranial pressure measurements.
A non-invasive method of assessing intracranial pressure (ICP) would be of benefit to patients with abnormal cerebral pathology that could give rise to changes in ICP. In particular, it would assist the regular monitoring of hydrocephalus patients. This study evaluated a technique using tympanic membrane displacement (TMD) measurements, which has been reported to provide a reliable, non-invasiv...
متن کاملReproducibility and accuracy of optic nerve sheath diameter assessment using ultrasound compared to magnetic resonance imaging
BACKGROUND Quantification of the optic nerve sheath diameter (ONSD) by transbulbar sonography is a promising non-invasive technique for the detection of altered intracranial pressure. In order to establish this method as follow-up tool in diseases with intracranial hyper- or hypotension scan-rescan reproducibility and accuracy need to be systematically investigated. METHODS The right ONSD of ...
متن کامل