Individual variations in human cone photoreceptor packing density: variations with refractive error.
نویسندگان
چکیده
PURPOSE To measure the variation in human cone photoreceptor packing density across the retina, both within an individual and between individuals with different refractive errors. METHODS A high-resolution adaptive optics scanning laser ophthalmoscope was used to image the cones of 11 human eyes. Five subjects with emmetropia and six subjects with myopia were tested (+0.50 to -7.50 D). For each subject, four approximately 10 degrees x 1.5 degrees strips of cone images were obtained. Each strip started at the fovea and proceeded toward the periphery along the four primary meridians. The position of each cone within the sampling windows was digitized manually by the investigator. From these cone counts, the density of the cones was calculated for a set of fixed distances from the fovea at locations throughout the image. RESULTS Cone photoreceptor packing density decreased from 27,712 cells/mm(2) to 7,070 cells/mm(2) from a retinal eccentricity of 0.30 to 3.40 mm along the superior meridian in five emmetropic eyes. Cone photoreceptor packing density (cells per square millimeter) was significantly lower in myopic eyes than in emmetropic eyes. At a given location, there was considerable individual variation in cone photoreceptor packing density, although more than 20% of the variance could be accounted for by differences in axial length. CONCLUSIONS The results provide a baseline analysis of individual difference in cone photoreceptor packing density in healthy human eyes. As predicted by retinal stretching models, cone photoreceptor packing density is lower in highly myopic eyes than in emmetropic eyes.
منابع مشابه
Adaptive-optics imaging of human cone photoreceptor distribution.
We have used an adaptive-optics scanning laser ophthalmoscope to image the cone photoreceptor mosaic throughout the central 10 degrees -12 degrees of the retina for four normal subjects. We then constructed montages of the images and processed the montages to determine cone locations. Cone densities range from approximately 10,000 cones/mm2 at 7 degrees to 40,000 cones/mm2 at 1 degrees . The sm...
متن کاملVariation of cone photoreceptor packing density with retinal eccentricity and age.
PURPOSE To study the variation of cone photoreceptor packing density across the retina in healthy subjects of different ages. METHODS High-resolution adaptive optics scanning laser ophthalmoscope (AOSLO) systems were used to systematically image the retinas of two groups of subjects of different ages. Ten younger subjects (age range, 22-35 years) and 10 older subjects (age range, 50-65 years)...
متن کامل[Corneal morphometric predictive models from ametropia to excimer laser treatment].
OBJECTIVE To develop corneal morphometric models with refractive error in excimer laser surgery. METHOD A prospective-longitudinal study was conducted on 78 patients (151 eyes) using the LASIK surgical technique, and 56 patients (111 eyes) with myopic astigmatism using ESIRIS (Schwind-Germany) equipment with pendulous microkeratome. The results were analyzed using descriptive statistics. A NI...
متن کاملCone photoreceptor definition on adaptive optics retinal imaging
AIMS To quantitatively analyse cone photoreceptor matrices on images captured on an adaptive optics (AO) camera and assess their correlation to well-established parameters in the retinal histology literature. METHODS High resolution retinal images were acquired from 10 healthy subjects, aged 20-35 years old, using an AO camera (rtx1, Imagine Eyes, France). Left eye images were captured at 5° ...
متن کاملEvaluation of Anatomical Variations of Paranasal Sinuses in Cone-beam Computed Tomography (CBCT) of Patients with Chronic Rhinosinusitis in Comparing with Normal Individuals
Introdouction: An exact knowledge of the anatomical variations of the paranasal sinuses (PNS) is critical for surgeons performing endoscopic sinus surgery and for radiologists involved in making preoperative evaluations. An important aspect is the determination of correlation between the anatomical variations of PNS and the presence of chronic rhinosinusitis (CR). Cone-beam computed tomograph...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 49 10 شماره
صفحات -
تاریخ انتشار 2008