Monte Carlo simulation on pre-clinical irradiation: A heterogeneous phantom study on monoenergetic kilovoltage photon beams

نویسنده

  • James C L Chow
چکیده

This study investigated radiation dose variations in pre-clinical irradiation due to the photon beam energy and presence of tissue heterogeneity. Based on the same mouse computed tomography image dataset, three phantoms namely, heterogeneous, homogeneous and bone homogeneous were used. These phantoms were generated by overriding the relative electron density of no voxel (heterogeneous), all voxel (homogeneous) and the bone voxel (bone homogeneous) to one. 360 o photon arcs with beam energies of 50 1250 keV were used in mouse irradiations. Doses in the above phantoms were calculated using the EGSnrc-based DOSXYZnrc code through the DOSCTP. Monte Carlo simulations were carried out in parallel using multiple nodes in a high-performance computing cluster. It was found that the dose conformity increased with the increase of the photon beam energy from the keV to MeV range. For the heterogeneous mouse phantom, increasing the photon beam energy from 50 keV to 1250 keV increased seven times the dose deposited at the isocenter. For the bone dose enhancement, the mean dose was 2.7 times higher when the bone heterogeneity was not neglected using the 50 keV photon beams in the mouse irradiation. Bone dose enhancement affecting the mean dose was found in the photon beams with energy range of 50 – 200 keV and the dose enhancement decreased with an increase of the beam energy. Moreover, the MeV photon beam had a higher dose at the isocenter, and a better dose conformity compared to the

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Monte Carlo Study on Dose Enhancement by Homogeneous and Inhomogeneous Distributions of Gold Nanoparticles in Radiotherapy with Low Energy X-rays

Background: To enhance the dose to tumor, the use of high atomic number elements has been proposed.Objective: The aim of this study is to investigate the effect of gold nanoparticle distribution on dose enhancement in tumor when the tumor is irradiated by typical monoenergetic X-ray beams by considering homogeneous and inhomogeneous distributions of gold nanoparticles (GNPs) in the tumor.Method...

متن کامل

Effect of photon beam energy, gold nanoparticle size and concentration on the dose enhancement in radiation therapy.

INTRODUCTION Gold nanoparticles have been used as radiation dose enhancing materials in recent investigations. In the current study, dose enhancement effect of gold nanoparticles on tumor cells was evaluated using Monte Carlo (MC) simulation. METHODS We used MCNPX code for MC modeling in the current study. A water phantom and a tumor region with a size of 1×1×1 cm3 loaded with gold nanopartic...

متن کامل

Estimation of Photon Specific Absorbed Fractions in Digimouse Voxel Phantom using Monte Carlo Simulation Code FLUKA

Background: Most preclinical studies are carried out on mice. For internal dose assessment of a mouse, specific absorbed fraction (SAF) values play an important role. In most studies, SAF values are estimated using older standard human organ compositions and values for limited source target pairs.Objective: SAF values for monoenergetic photons of energies 15, 50, 100, 500, 1000 and 4000 keV...

متن کامل

The Impact of Nano-Sized Gold Particles on the Target Dose Enhancement Based on Photon Beams Using by Monte Carlo Method

Objective(s): In this study we evaluate the impact of the different aspects of Gold Nano-Particles (GNPs) on the target absorptive Dose Enhancement Factor (DEF) during external targeted radiotherapy with photon beams ranging from kilovolt to megavolt energies using Monte Carlo simulation. Methods: We have simulated the interaction of photon beams wi...

متن کامل

Evaluation of Electron Contamination in Cancer Treatment with Megavoltage Photon Beams: Monte Carlo Study

Background: Megavoltage beams used in radiotherapy are contaminated with secondary electrons. Different parts of linac head and air above patient act as a source of this contamination. This contamination can increase damage to skin and subcutaneous tissue during radiotherapy. Monte Carlo simulation is an accurate method for dose calculation in medical dosimetry and has an important role in opt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012