Broadband versus stepped sine FRF measurements
نویسندگان
چکیده
In this paper, the required measurement time to measure a transfer function with a specified accuracy is analyzed. The waiting time that is needed to balance the transient induced errors against the noise errors is calculated. This allows one to decide under what conditions broad-band measurements are faster than stepped sine measurements.
منابع مشابه
An FPGA-based frequency response analyzer for multisine and stepped sine measurements on stationary and time-varying impedance
We report the development of a field programmable gate array (FPGA) based frequency response analyzer (FRA) for impedance frequency response function (FRF) measurements using periodic excitations, i.e. sine waves and multisines. The stepped sine measurement uses two dedicated hardware-built digital embedded multiplier blocks to extract the phase and quadrature components of the output signal. T...
متن کاملBroadband Vibration Measurements Using a Continuously Scanning Laser Vibrometer
In this article we will apply the continuously scanning vibrometer measurement principle introduced in literature for stepped sine measurementsto broadband excitations. Special attention will be given to the errors which are introduced in the procedure. Also, a method will be proposed to estimate the complexity of the vibration patterns. Different scanning signals to cover the measured area of ...
متن کاملLateralization of Huggins pitch.
The Huggins pitch is a sensation of pitch generated from a broadband noise having a narrowband boundary region where the interaural phase difference varies rapidly as a function of frequency. Models of binaural hearing predict that the pitch image should be well lateralized. A direct psychophysical experimental method was used to estimate the lateral positions of Huggins pitch images with two d...
متن کاملStepped Spillway Performance: Study of the Pressure and Turbulent Kinetic Energy versus Discharge and Slope
In the present study, flow over flat and pooled stepped spillways was simulated three dimensionally. The VOF method and k- ε (RNG) turbulent model was used to simulate the flow over the stepped spillway. The results indicated that the numerical model was acceptably capable of simulating the flow over the pooled and flat stepped spillways for different discharges. Following that, the effect of d...
متن کاملImproved FRF estimators for MIMO Sine Sweep data
The dynamic identification of large aerospace structures like satellites, launcher components or aircraft prototypes, requires a great experimental effort in order to assure high quality test results. At the same time, because of the high development costs, a reduction of the test time is needed. In this paper, a test strategy capable to reduce the overall time required to perform dynamic tests...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- IEEE Trans. Instrumentation and Measurement
دوره 49 شماره
صفحات -
تاریخ انتشار 2000