Tibial plateau fractures: reproducibility of three classifications (Schatzker, AO, Duparc) and a revised Duparc classification.
نویسندگان
چکیده
INTRODUCTION Since the reproducibility of the Schatzker and AO tibial plateau fracture classification systems has already been assessed, the goal of this study was to evaluate the Duparc classification system and compare it to the other two. HYPOTHESES CT scan is better than X-rays for analyzing and classifying tibial plateau fractures. The Duparc classification system is more effective than the other two systems but could be improved by adding elements of each. MATERIALS AND METHODS Six observers analyzed images from 50 fractures and then classified them. Each fracture was evaluated on X-rays. Two weeks later, these same fractures were evaluated on X-rays and CT scans. The same process was repeated four weeks later. The Kappa coefficient (κ) was used to measure agreement and contingency tables were built. RESULTS The interobserver reproducibility for the X-ray analysis was poor for the Duparc and AO classifications (κDuparc=0.365; κAO=0.357) and average for the Schatzker classification (κSchatzker=0.404). The reproducibility was improved overall when CT scans were also analyzed (κDuparc=0.474; κAO=0.479; κSchatzker=0.476). A significantly greater number of fractures could not be classified in the Schatzker system than in the others (14.3% versus 2% for Duparc and 7.33% for AO). Review of the contingency tables revealed that the Schatzker and AO classification systems did not take certain fracture types into account. Seventy-one percent (71%) of the lateral unicondylar split fractures were found to be combined fractures when CT scan analysis was added. DISCUSSION Our results showed CT scan to be better at analyzing and classifying fractures. We also found the Duparc classification to be advantageous because it allowed more fractures to be classified than in other classification systems, while having similar reproducibility. Based on our study findings, the Duparc classification was revised by adding elements of the other two. We propose using the modified Duparc classification system to analyze tibial plateau fractures going forward. LEVEL OF EVIDENCE Level IV. Retrospective study.
منابع مشابه
Inter-observer reliability assessment of the Schatzker, AO/OTA and three-column classification of tibial plateau fractures
BACKGROUND The purpose of our study was to evaluate inter-observer reliability of the Three-Column classifications with conventional Schatzker and AO/OTA of Tibial Plateau Fractures. METHODS 50 cases involving all kinds of the fracture patterns were collected from 278 consecutive patients with tibial plateau fractures who were internal fixed in department of Orthopedics and Trauma III in Shan...
متن کاملCharacteristics of unilateral tibial plateau fractures among adult patients hospitalized at an orthopaedic trauma centre in China
The aim of this study was to investigate the characteristics of unilateral tibial plateau fractures among hospitalized adult patients in Xijing Hospital, to evaluate the accuracy of Schatzker classification system and AO/OTA classification system to tibial plateau fractures. We retrospectively analysed clinical data on 274 patients admitted to Xijing Hospital between September 2006 and August 2...
متن کاملClassifications in brief: Schatzker classification of tibial plateau fractures.
Early attempts at classifying tibial plateau fractures by Palmer in 1951 [25], Hohl and Luck in 1956 [15], and Hohl in 1967 [15] recognized some of the major themes common to many classification systems for these fractures: split of a condyle, subchondral depression, and comminuted bicondylar involvement. Schatzker et al. published their classification system in 1979 [29], deriving it from the ...
متن کاملFunctional Outcome and Incidence of Osteoarthritis in Operated Tibial Plateau Fractures
Background: In the challenging tibial condyle fractures despite anatomical joint reconstruction, development ofosteoarthritis may still occur secondary to the initial articular cartilage and meniscal injury. The aim of the study wasto know incidence of osteoarthritis in our operated cases of tibial plateau fracture and to evaluate functional outcome.Methods: Our operated 60 patients of tibial p...
متن کاملSchatzker type IV medial tibial plateau fractures: a computed tomography-based morphological subclassification.
Schatzker type IV medial tibial plateau fractures have an unfavorable prognosis, likely due to the mechanism of injury (fracture-dislocation/subluxation type) and possibly due to the involvement of the posterolateral plateau, which is different from previously thought. The aim of this study was to propose a new subclassification of Schatzker type IV fracture patterns based on 2-dimensional (2-D...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Orthopaedics & traumatology, surgery & research : OTSR
دوره 99 7 شماره
صفحات -
تاریخ انتشار 2013