Development of Kinematic Graphs of Median Nerve during Active Finger Motion: Implications of Smartphone Use
نویسندگان
چکیده
BACKGROUND Certain hand activities cause deformation and displacement of the median nerve at the carpal tunnel due to the gliding motion of tendons surrounding it. As smartphone usage escalates, this raises the public's concern whether hand activities while using smartphones can lead to median nerve problems. OBJECTIVE The aims of this study were to 1) develop kinematic graphs and 2) investigate the associated deformation and rotational information of median nerve in the carpal tunnel during hand activities. METHODS Dominant wrists of 30 young adults were examined with ultrasonography by placing a transducer transversely on their wrist crease. Ultrasound video clips were recorded when the subject performing 1) thumb opposition with the wrist in neutral position, 2) thumb opposition with the wrist in ulnar deviation and 3) pinch grip with the wrist in neutral position. Six still images that were separated by 0.2-second intervals were then captured from the ultrasound video for the determination of 1) cross-sectional area (CSA), 2) flattening ratio (FR), 3) rotational displacement (RD) and 4) translational displacement (TD) of median nerve in the carpal tunnel, and these collected information of deformation, rotational and displacement of median nerve were compared between 1) two successive time points during a single hand activity and 2) different hand motions at the same time point. Finally, kinematic graphs were constructed to demonstrate the mobility of median nerve during different hand activities. RESULTS Performing different hand activities during this study led to a gradual reduction in CSA of the median nerve, with thumb opposition together with the wrist in ulnar deviation causing the greatest extent of deformation of the median nerve. Thumb opposition with the wrist in ulnar deviation also led to the largest extent of TD when compared to the other two hand activities of this study. Kinematic graphs showed that the motion pathways of median nerve during different hand activities were complex. CONCLUSION We observed that the median nerve in the carpal tunnel was rotated, deformed and displaced during the hand activities that people may be performed when using a smartphone, suggesting an increased risk of carpal tunnel syndrome (CTS). In addition, the kinematic graphs of median nerve developed in the present study provide new clues for further studies on the pathophysiology of CTS, and alerting smartphone users to establish proper postural habits when using handheld electronic devices.
منابع مشابه
Examining the Effect of Smartphone on Musculoskeletal Disorders and Neck Kinematic Among Smartphone Users in Different Postures and Tasks
Background and Objectives: In the last decade, the smartphones have become one of the most popular technologies around the world. Due to the multi-functional use of smartphones, the technology users spend long hours using it. Methods: This was a semi-experimental and experimental study. In the first section, 98 students entered the semi-experimental part and completed demographic and body map ...
متن کاملChanges in Gait Pattern During Smartphone and Tablet Use
Objectives: There exists no study concerning gait pattern while engaging in dual-task activities on different sizes of mobile devices. The present study aimed to compare gait patterns during normal walking, walking with smartphone use, and walking with tablet use. Methods: Seventeen healthy female participants with an age range of 19-24 years (mean±SD age: 20.29±1.61 years, weight: 49.82±4.46...
متن کاملحرکت ارادی پتانسیل های ناشی از قشر حسی پیکری را تعدیل می کند
An early component of the somatosensory evoked potential, arising from the primary sensory cortex in man is attenuated during voluntary finger movement. The median nerve at the wrist was stimulated while the subject performed fractionated finger movements with the same hand. Subcortical components of the somatosensory evoked potential were not changed but the P25 cortical component was attenuat...
متن کاملTransverse Plane Tendon and Median Nerve Motion in the Carpal Tunnel: Ultrasound Comparison of Carpal Tunnel Syndrome Patients and Healthy Volunteers
BACKGROUND The median nerve and flexor tendons are known to translate transversely in the carpal tunnel. The purpose of this study was to investigate these motions in differential finger motion using ultrasound, and to compare them in healthy people and carpal tunnel syndrome patients. METHODS Transverse ultrasounds clips were taken during fist, index finger, middle finger and thumb flexion i...
متن کاملVelocity-dependent changes in the relative motion of the subsynovial connective tissue in the human carpal tunnel.
The purpose of this study was to measure the rate-dependent changes in the relative motion of subsynovial connective tissue (SSCT) and median nerve in the human carpal tunnel. Using fluoroscopy, we measured the relative motion of middle finger flexor digitorum superficialis tendon, SSCT, and median nerve in eight human cadavers during simulated active finger flexion motions at 2.0, 5.0, 7.5, an...
متن کامل