In‐house auto cutoff sensor device for radiotherapy machine to monitor patient movements
نویسندگان
چکیده
Radiotherapy is an effective treatment method for cancers. During radiation treatment, a patient must be in the same position from the start to the end of radiation treatment. Patient movements are usually monitored by the radiation technologists through the closed circuit television (CCTV) during treatment. If the patient makes a small movement, it is difficult to be noticed by them. In the present work, a simple patient movement monitoring device (PMMD) is fabricated to monitor the patient movement. It uses an electronic sensing device. It continuously monitors the patient's position while the radiation treatment is in process. The device has been retrospectively tested on 86 patients whose movement and distance were measured. The results show that 24 patients moved 1 cm to 2.5 cm from their initial position during the external beam radiotherapy (EBRT). Hence, the device can potentially be used to control and monitor patient movement during EBRT. In addition, an audible alarm situated at the control panel of the treatment room is provided with this device to alert the radiation technologists. It is an inexpensive, compact device which can be used in any radiotherapy machine. It can prevent patients from being treated in a wrong position and therefore improve the quality of the radiation treatment.
منابع مشابه
Standard edge detection algorithms versus conventional auto-contouring used for a three-dimensional rigid CT-CT matching
Background: To reduce uncertainties of patient positioning, the Computerized Tomography (CT) images acquired at the treatment planning time can be compared with those images obtained during radiation dose delivery. This can be followed during dose delivery procedure as Image Guided radiotherapy (IGRT) to verify the prescribed radiation dose delivery to the target as well as to monitor ...
متن کاملPurpose:The purpose of our study was to fabricate in-house web-camera based automatic continuous patient movement monitoring device and control the movement of the patients during EXRT
ID: 18085 Title: Design and Study of In-House Web-Camera Based Automatic Continuous Patient Movement Monitoring and Controlling Device for EXRT Purpose:The purpose of our study was to fabricate in-house web-camera based automatic continuous patient movement monitoring device and control the movement of the patients during EXRT. Methods:Web-camera based patient movement monitoring device consist...
متن کاملVerification of Monitor unit calculations for eclipse Treatment Planning System by in- house developed spreadsheet
Introduction: Computerized treatment planning is a rapidly evolving modality that depends on hardware and software efficiency. Despite ICRU recommendations suggesting 5% deviation in dose delivery the overall uncertainty shall be less than 3.5% as suggested by B.J. Minjnheer. J. In house spreadsheets are developed by the medical physicists to cross-verify the dose calculated by the Treatment Pl...
متن کامل2D linear array device as a quality assurance tool in brachytherapy applications
Background: External beam radiotherapy and brachytherapy plays a vital role in the management of cancer cervix. High dose rate brachytherapy is being presently used worldwide for the brachytherapy applications. At present, 2-Dimensional linear array detectors are the most common QA tool used for pretreatment patient specific quality assurance in external beam radiotherapy alon...
متن کاملDesign and Implementation of an Exergame Using Image Processing Techniques for Telerehabilitation of Patients with Physical Disabilities
Introduction: In recent years, due to physical problems of patients or restrictions on social interactions in COVID-19 pandemic, telerehabilitation based on virtual reality (VR) attracted the attention of many researchers. Method: In this applied research, a Kinect sensor and an image processing software were used to design and implement a motion simulator for rehabilitation of patients with...
متن کاملذخیره در منابع من