Sensitive detection of tetracyclines using europium-sensitized fluorescence with EDTA as co-ligand and cetyltrimethylammonium chloride as surfactant.

نویسندگان

  • N Arnaud
  • J Georges
چکیده

The determination of tetracyclines (TC) in aqueous solutions, based on europium-sensitized fluorescence, has been improved using EDTA as co-ligand and cetyltrimethylammonium chloride as surfactant. The method involves working in slightly alkaline solutions with the formation of a new chelate where the lanthanide ion is bound to the beta-diketone group. The method is about 6 times more sensitive than that with the Eu-TC-Triton system and LODs are 2.5 x 10(-10), 5 x 10(-10), 1.5 x 10(-9) and 2 x 10(-9) mol l-1 for TC, oxytetracycline, chlortetracycline and doxycycline, respectively. The method has been applied to the determination of TC in calf serum without sample pretreatment. The mean recovery was close to 102% and the lowest concentration attainable in serum samples was better than 0.1 microgram ml-1.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of a Simple and Sensitive Terbium Sensitized Fluorescence Method for Determination of Epinephrine and Norepinephrine in Serum

     A simple, rapid, selective and highly sensitive fluorimetric method for determination of two catecholamines, i.e. norepinephrine (NE) and epinephrine (EP), in serum samples was developed. The method is based on the fluorescence sensitization of terbium (Tb3+) by complexation with both catecholamines in the presence of lanthanum (La3+), as a co-cation, and in a Na...

متن کامل

Synergetic signal amplification of multi-walled carbon nanotubes-Cetyltrimethylammonium Bromide and Poly-L-Arginine as a highly sensitive detection platform for Rutin

In this research, a glassy carbon electrode was coated with a thin layer of multi-walled carbon nanotubes in the presence of the surfactant and subsequently was electro-polymerized with Poly-L-arginine (P-L-Arg). The prepared electrode was used as an effective sensor for the quantitative detection of Rutin (Ru). The fabricated electrode exhibited good electrochemical performance with low electr...

متن کامل

Synergetic signal amplification of multi-walled carbon nanotubes-Cetyltrimethylammonium Bromide and Poly-L-Arginine as a highly sensitive detection platform for Rutin

In this research, a glassy carbon electrode was coated with a thin layer of multi-walled carbon nanotubes in the presence of the surfactant and subsequently was electro-polymerized with Poly-L-arginine (P-L-Arg). The prepared electrode was used as an effective sensor for the quantitative detection of Rutin (Ru). The fabricated electrode exhibited good electrochemical performance with low electr...

متن کامل

Fe-Loaded CeO2 Nanosized Prepared by Simple Co-Precipitation Route

FeCe nanoparticles were synthesized by simple co-precipitation method using Iron chloride hexahydrate (FeCl3.6H2O) and cerium chloride (CeCl2•5H2O) as precursors in the presence of cetyltrimethylammonium bromide (CTAB) surfactant. The samples were characterized by high resolution transmission electron microscopy (HRTEM), field emission scanning electron microscopy (FESEM), X-ray diffraction (XR...

متن کامل

Micellar-enhanced photochemically induced fluorescence detection of chlorophenoxyacid herbicides. Flow injection analysis of mecoprop and 2,4-dichlorophenoxyacetic acid.

In this paper, a combination of a flow injection analysis (FIA) system with micellar-enhanced photochemically induced fluorescence (MEPIF) detection is presented as a powerful alternative for the rapid and sensitive analysis of chlorophenoxyacid herbicides. These compounds do not show native fluorescence but they can be photolysed into strongly fluorescence photoproducts after direct irradiatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 126 5  شماره 

صفحات  -

تاریخ انتشار 2001