Pii: S0301-5629(00)00316-1
نویسندگان
چکیده
Spectral estimation of tissue strain has been performed previously by using the centroid shift of the power spectrum or by estimating the variation in the mean scatterer spacing in the spectral domain. The centroid shift method illustrates the robustness of the direct, incoherent strain estimator. In this paper, we present a strain estimator that uses spectral cross-correlation of the preand postcompression power spectrum. The centroid shift estimator estimates strain from the mean center frequency shift, while the spectral cross-correlation estimates the shift over the entire spectrum. Spectral cross-correlation is shown to be more sensitive to small shifts in the power spectrum and, thus, provides better estimation for smaller strains when compared to the spectral centroid shift. Spectral cross-correlation shares all the advantages gained using the spectral centroid shift, in addition to providing accurate and precise strain estimation for small strains. The variance and noise properties of the spectral strain estimators quantified by their respective strain filters are also presented. © 2001 World Federation for Ultrasound in Medicine & Biology.
منابع مشابه
Pii: S0301-5629(01)00472-0
The nonstationary variation in the noise performance of the cross-correlation-based strain estimator due to frequency-dependent attenuation and lateral and elevational signal decorrelation have been addressed theoretically in recent papers using the strain-filter approach. In this paper, we present the experimental verification and corroboration of the nonstationary effects on the strain estima...
متن کاملPii: S0301-5629(00)00278-7
Physiological study of the developing mouse circulation has lagged behind advances in molecular cardiology. Using an innovative high-frequency Doppler system, we noninvasively characterized circulatory hemodynamics in early mouse embryos. We used image-guided 43 MHz pulsed-wave (PW) Doppler ultrasound to study the umbilical artery and vein, or dorsal aorta in 109 embryos. Studies were conducted...
متن کاملPii: S1010-7940(00)00316-x
A direct laryngoscope-assisted technique of saphenous vein harvesting by tunnelling method is described. This technique provides better exposure through small incisions, thus reducing the chances of trauma to the vein due to excessive handling. The equipment used is inexpensive and readily available. q 2000 Elsevier Science B.V. All rights reserved.
متن کاملPii: S0301-5629(01)00478-1
In this paper we propose a novel feature-based contrast enhancement approach to enhance the quality of noisy ultrasound (US) images. Our approach uses a phase-based feature detection algorithm, followed by sparse surface interpolation and subsequent nonlinear postprocessing. We first exploited the intensity-invariant property of phase-based acoustic feature detection to select a set of relevant...
متن کاملPii: S0301-5629(01)00495-1
The limits and trade-offs of the axial resolution in elastography were investigated using a controlled simulation study. The axial resolution in elastography was estimated as the distance between the full widths at half-maximum of the strain profiles of two equally stiff lesions embedded in a softer homogeneous background. The results show that the upper bound of the axial resolution in elastog...
متن کامل