Assessment of swallowing and masticatory performance in obturator wearers: a clinical study

نویسندگان

  • Nungotso Vero
  • Niraj Mishra
  • Balendra Pratap Singh
  • Kamleshwar Singh
  • Sunit Kumar Jurel
  • Vijay Kumar
چکیده

PURPOSE To assess function by identifying changes in swallowing and masticatory performance in maxillary obturator prosthesis wearers. MATERIALS AND METHODS Sixty subjects were recruited for the study, of which 20 were obturator wearers, 20 were completely dentulous and 20 had removable partial/complete dentures with similar Eichner's Index. Swallowing ability was evaluated with and without obturator using the "Water Drinking Test"; Masticatory performance was evaluated with the Sieve test; and maximum occlusal force was recorded with the help of a digital bite sensor. The data was analyzed using the Statistical Package for Social Science version 15.0 with a confidence level at 95%. RESULTS Profile, behavior of drinking and time taken to drink were significantly improved (P<.001) in subjects after wearing obturator. Masticatory performance was not significantly different (P=.252) in obturator wearer when compared with dentulous or removable partial/complete denture wearer, but significantly (P<.001) high inter group difference in maximum occlusal force existed. Correlation between masticatory performance and maximum occlusal force was not significant (P=.124). CONCLUSION Swallowing ability was significantly improved after wearing obturator but masticatory performance was not significantly different from those having similar occlusal support zone in their dentition.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Partial removable prosthesis in a patient with unilateral maxillectomy: A case report

BACKGROUND AND AIM: Maxillofacial defects due to malignant or benign tumors or congenital defects often result in complications such as the impairment of facial aesthetic, mastication, speech, and swallowing. Remedy of these defects, especially in a dentate patient is an important challenge in prosthodontics. Maxillectomy can lead to severe anatomical changes f...

متن کامل

Methods for evaluation of masticatory efficiency in conventional complete denture wearers: a systematized review.

The objective of this study was to present a systematized review of different methods used to evaluate the masticatory efficiency in conventional complete denture wearers. A survey was conducted in the databases PubMed, Scopus, and Cochrane, seeking scientific articles according to the previously selected terms: "Masticatory performance", "Masticatory efficiency" and "Chewing ability complete d...

متن کامل

Analysis of the mechanical properties of food bolus masticated by denture wearers.

Masticatory performance of denture wearers was compared with that of the normal subjects by analyzing the behavior of the mechanical properties of the bolus. The index of the ability to comminute bolus was described as the total number of masticatory strokes until swallowing and therefore this was chosen as the first index. Principal Component Analysis (PCA) on the data of six parameters; 80% e...

متن کامل

Prosthetic rehabilitation of a complete bilateral maxillectomy patient using a simple magnetically connected hollow obturator: a case report.

AIM The purpose of this clinical report is to present a description of the prosthetic rehabilitation of a bilateral complete maxillectomy patient using a two piece magnetically connected prosthesis. BACKGROUND A complete bilateral maxillectomy defect presents a considerable reconstructive challenge for the prosthodontist. It results in devastating effects on cosmetic, functional, and psycholo...

متن کامل

A clinical study to evaluate and compare the masticatory performance in complete denture wearers with and without soft liners.

AIMS AND OBJECTIVES Soft liners are mainly used with complete dentures in case of poor mucosal conditions and for the even distribution of masticatory forces. However, there is some doubt as to whether the elasticity of the soft liner disturbs masticatory function because denture wearers may need extra force to compress the soft liners, leading to muscle fatigue. So, this clinical study was don...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2015