Chemiluminescence determination of melamine with Luminol-K3Fe(CN)6 system
نویسندگان
چکیده
A sensitive chemiluminescence (CL) method was developed for determining melamine in urine and plasma samples based on the fact that melamine can remarkably enhance the chemiluminescence of Luminol-K3 Fe(CN)6 system in alkaline medium. The determination conditions were optimized. Under optimum conditions, the chemiluminescence intensity had a good linear relationship with melamine in the range of 9.0 × 10-9 - 7.0 × 10-6 g/mL with a correlation coefficient of 0.9992. The detection limits (3σ) were 3.54 ng/mL for urine sample and 6.58 ng/mL for plasma sample. The average recoveries of melamine were 102.6% for urine sample and 95.1% for plasma sample. Melamine in samples was extracted with liquid-liquid extraction procedures and the assay results coincided very well with that determined with flow injection chemiluminescence method. The method provides a reproducible and stable approach for sensitive detection and quantification of melamine in urine and plasma samples.
منابع مشابه
Luminol–K3Fe(CN)6 chemiluminescence system for the determination of glipizide
A rapid and sensitive flow-injection chemiluminescence (CL) method for the determination of glipizide was developed on the basis of finding that glipizide can enhance the CL intensity of the luminol-K3Fe(CN)6 system. In optimum condition, the increased CL intensity was directly proportional to the concentration of glipizide in the range from 4.0×10-8 g/mL to 1.0×10-6 g/mL and the detection limi...
متن کاملSimultaneous determination of N,N-dimethylaniline and phenol in wastewater by high-performance liquid chromatography with chemiluminescence detection.
A method using HPLC-CL linkage was developed for simultaneous determination of N,N-dimethylaniline and phenol in wastewater, based on the strong sensitive chemiluminescence of the luminol-K3Fe(CN)6 systems in alkaline medium. The separation was carried out on a Hypersil ODS column with a mobile phase of ethanol-0.01% triethylamine (2:1, v/v). The linear ranges for N,N-dimethylaniline determinat...
متن کاملChemiluminescence Determination of Atropine using Luminol-Hemin-H2O2 System
A sensitive and fast chemiluminescence (CL) method has been described for the direct determination of atropine. The method is based on the quenching effect of atropine on the CL signals of the luminol– H2O2 reaction catalyzed by hemin in an alkaline medium. Hemin could strongly enhance the chemiluminescence of the luminol–H2O2 system. The luminophor of the luminol–H2O2–hemin CL system was ident...
متن کاملDevelopment of FIA equipped with a chemiluminescence detector using a mixed reagent of luminol and 1,10-phenanthroline.
We developed an FIA system equipped with a chemiluminescence detector using a mixed chemiluminescence reagent of luminol and 1,10-phenanthroline for the detection of metal ions and metal complexes. The carrier, mixed chemiluminescence reagent comprising luminol, 1,10-phenanthroline, and cethyltrimethylammonium bromide, and H2O2 solutions were fed by corresponding pumps at a definite flow rate. ...
متن کاملDirect Chemiluminescence Determination of Oxymorphone Using Potassium Permanganate and Polyphosphoric Acid
Abstract A simple and sensitive chemiluminescence (CL) method was developed for direct quantification of oxymorphone, a µ opioid agonist that is approximately 10 times more potent than morphine. In this method potassium permanganate in polyphosphoric acid was used as CL reagent. Using this method, oxymorphone can be determined over the concentration ranges 13.5-337.8 ng mL-1 and 0.34-6.76...
متن کامل