Cationic versus neutral microbubbles for ultrasound-mediated gene delivery in cancer.

نویسندگان

  • David S Wang
  • Cedric Panje
  • Marybeth A Pysz
  • Ramasamy Paulmurugan
  • Jarrett Rosenberg
  • Sanjiv S Gambhir
  • Michel Schneider
  • Jürgen K Willmann
چکیده

PURPOSE To test whether plasmid-binding cationic microbubbles (MBs) enhance ultrasound-mediated gene delivery efficiency relative to control neutral MBs in cell culture and in vivo tumors in mice. MATERIALS AND METHODS Animal studies were approved by the institutional animal care committee. Cationic and neutral MBs were characterized in terms of size, charge, circulation time, and DNA binding. Click beetle luciferase (CBLuc) reporter plasmids were mixed with cationic or neutral MBs. The ability of cationic MBs to protect bound plasmids from nuclease degradation was tested by means of a deoxyribonuclease (DNase) protection assay. Relative efficiencies of ultrasound-mediated transfection (ultrasound parameters: 1 MHz, 1 W/cm(2), 20% duty cycle, 1 minute) of CBLuc to endothelial cells by using cationic, neutral, or no MBs were compared in cell culture. Ultrasound-mediated gene delivery to mouse hind limb tumors was performed in vivo (n = 24) with insonation (1 MHz, 2 W/cm(2), 50% duty cycle, 5 minutes) after intravenous administration of CBLuc with cationic, neutral, or no MBs. Tumor luciferase activity was assessed by means of serial in vivo bioluminescence imaging and ex vivo analysis. Results were compared by using analysis of variance. RESULTS Cationic MBs (+15.8 mV; DNA binding capacity, 0.03 pg per MB) partially protected bound DNA from DNase degradation. Mean CBLuc expression of treated endothelial cells in culture was 20-fold higher with cationic than with neutral MBs (219.0 relative light units [RLUs]/µg protein ± 92.5 [standard deviation] vs 10.9 RLUs/µg protein ± 2.7, P = .001) and was significantly higher (P < .001) than that in the no MB and no ultrasound control groups. Serial in vivo bioluminescence of mouse tumors was significantly higher with cationic than with neutral MBs ([5.9 ± 2.2] to [9.3 ± 5.2] vs [2.4 ± 0.8] to [2.9 ± 1.1] × 10(4) photons/sec/cm(2)/steradian, P < .0001) and versus no MB and no ultrasound controls (P < .0001). Results of ex vivo analysis confirmed these results (ρ = 0.88, P < .0001). CONCLUSION Plasmid-binding cationic MBs enhance ultrasound-mediated gene delivery efficiency relative to neutral MBs in both cell culture and mouse hind limb tumors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Studies on neutral, cationic and biotinylated cationic microbubbles in enhancing ultrasound-mediated gene delivery in vitro and in vivo.

Ultrasound-mediated gene transfer is emerging as a practical means of facilitating targeted gene expression and is significantly enhanced in the presence of exogenously added microbubbles. This study explores the influence of microbubble surface modifications on their interaction with plasmid DNA and target cells, and the functional consequences of those interactions in terms of ultrasound-medi...

متن کامل

Ultrasound-Mediated Gene Delivery with Cationic Versus Neutral Microbubbles: Effect of DNA and Microbubble Dose on In Vivo Transfection Efficiency

OBJECTIVE To assess the effect of varying microbubble (MB) and DNA doses on the overall and comparative efficiencies of ultrasound (US)-mediated gene delivery (UMGD) to murine hindlimb skeletal muscle using cationic versus neutral MBs. MATERIALS AND METHODS Cationic and control neutral MBs were characterized for size, charge, plasmid DNA binding, and ability to protect DNA against endonucleas...

متن کامل

Localized Delivery of shRNA against PHD2 Protects the Heart from Acute Myocardial Infarction through Ultrasound-Targeted Cationic Microbubble Destruction

Hypoxia-inducible factor 1α (HIF-1α) plays a critical protective role in ischemic heart disease. Under normoxic conditions, HIF-1α was degraded by oxygen-dependent prolyl hydroxylase-2 (PHD2). Gene therapy has become a promising strategy to inhibit the degradation of HIF-1α and to improve cardiac function after ischemic injury. However, conventional gene delivery systems are difficult to achiev...

متن کامل

Experimental endostatin-GFP gene transfection into human retinal vascular endothelial cells using ultrasound-targeted cationic microbubble destruction

PURPOSE The purpose of this study was to investigate whether ultrasound-targeted cationic microbubble destruction could effectively deliver endostatin-green fluorescent protein (ES-GFP) plasmids to human retinal vascular endothelial cells (HRECs). METHODS Cationic microbubbles (CMBs) were prepared and then compared with neutral microbubbles (NMBs) and liposomes. First, the two types of microb...

متن کامل

Cationic gas-filled microbubbles for ultrasound-based nucleic acids delivery

The use of ultrasound has gained great interest for nucleic acids delivery. Ultrasound can reach deep tissues in non-invasive manner. The process of sonoporation is based on the use of low-frequency ultrasound combined with gas-filled microbubbles (MBs) allowing an improved delivery of molecules including nucleic acids in the insonified tissue. For in vivo gene transfer, the engineering of cati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 264 3  شماره 

صفحات  -

تاریخ انتشار 2012