Nanosizing of fluorescent objects by spatially modulated illumination microscopy.
نویسندگان
چکیده
A new approach to measuring the sizes of small fluorescent objects by use of spatially modulated illumination (SMI) far-field light microscopy is presented. This method is based on SME measurements combined with a new SMI virtual microscopy (VIM) data analysis calibration algorithm. Here, experimental SMI measurements of fluorescent objects with known diameter (size) were made. From the SMI data obtained, the size was determined in an independent way by use of the SMI VIM algorithm. The results showed that with SMI microscopy in combination with SMI VIM calibration, subwavelength object size measurements as small as 40 nm are experimentally feasible with high accuracy.
منابع مشابه
Spatially Modulated Illumination Microscopy
Using Spectral Precision Distance Microscopy (SPDM) it is possible to measure positions and multiple distances between point-like fluorescent objects labelled with different spectral signatures far below the optical resolution criterion. In this paper, we report measurements and data acquisition using a Spatially Modulated Illumination (SMI) microscope. Furthermore, we studied some aspects of t...
متن کاملMeasuring the size of biological nanostructures with spatially modulated illumination microscopy.
Spatially modulated illumination fluorescence microscopy can in theory measure the sizes of objects with a diameter ranging between 10 and 200 nm and has allowed accurate size measurement of subresolution fluorescent beads ( approximately 40-100 nm). Biological structures in this size range have so far been measured by electron microscopy. Here, we have labeled sites containing the active, hype...
متن کاملMeasuring the Size of Biological Nanostructures with Spatially Modulated Illumination Microscopy□D
Spatially modulated illumination fluorescence microscopy can in theory measure the sizes of objects with a diameter ranging between 10 and 200 nm and has allowed accurate size measurement of subresolution fluorescent beads ( 40–100 nm). Biological structures in this size range have so far been measured by electron microscopy. Here, we have labeled sites containing the active, hyperphosphorylate...
متن کاملStructured illumination enhances resolution and contrast in thick tissue fluorescence imaging.
We introduce a noncontact imaging method utilizing multifrequency structured illumination for improving lateral and axial resolution and contrast of fluorescent molecular probes in thick, multiple-scattering tissue phantoms. The method can be implemented rapidly using a spatial light modulator and a simple image demodulation scheme similar to structured light microscopy in the diffraction regim...
متن کاملNano-sizing of specific gene domains in intact human cell nuclei by spatially modulated illumination light microscopy.
Although light microscopy and three-dimensional image analysis have made considerable progress during the last decade, it is still challenging to analyze the genome nano-architecture of specific gene domains in three-dimensional cell nuclei by fluorescence microscopy. Here, we present for the first time chromatin compaction measurements in human lymphocyte cell nuclei for three different, speci...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied optics
دوره 41 34 شماره
صفحات -
تاریخ انتشار 2002