The effect of Er:YAG laser irradiation on the surface microstructure and roughness of hydroxyapatite-coated implant
نویسندگان
چکیده
PURPOSE The present study was performed to evaluate the effect of erbium:yttrium-aluminium-garnet (Er:YAG) laser irradiation on the change of hydroxyapatite (HA)-coated implant surface microstructure according to the laser energy and the application time. METHODS The implant surface was irradiated by Er:YAG laser under combination condition using the laser energy of 100 mJ/pulse, 140 mJ/pulse and 180 mJ/pulse and application time of 1 minute, 1.5 minutes and 2 minutes. The specimens were examined by surface roughness evaluation and scanning electron microscopic observation. RESULTS In scanning electron microscope, HA-coated implant surface was not altered by Er:YAG laser irradiation under experimental condition on 100 mJ/pulse, 1 minute. Local areas with surface melting and cracks were founded on 100 mJ/pulse, 1.5 minutes and 2 minutes. One hundred forty mJ/pulse and 180 mJ/pulse group had surface melting and peeling area of HA particles, which condition was more severe depending on the increase of application time. Under all experimental condition, the difference of surface roughness value on implant surface was not statistically significant. CONCLUSIONS Er:YAG laser on HA-coated implant surface is recommended to be irradiated below 100 mJ/pulse, 1 minute for detoxification of implant surface without surface alteration.
منابع مشابه
The effect of erbium-doped: yttrium, aluminium and garnet laser irradiation on the surface microstructure and roughness of double acid-etched implants
PURPOSE One of the most frequent complications related to dental implants is peri-implantitis, and the characteristics of implant surfaces are closely related to the progression and resolution of inflammation. Therefore, a technical modality that can effectively detoxify the implant surface without modification to the surface is needed. The purpose of this study was to evaluate the effect of er...
متن کاملEffect of erbium-doped: yttrium, aluminium and garnet laser irradiation on the surface microstructure and roughness of sand-blasted, large grit, acid-etched implants
PURPOSE The present study was performed to evaluate the effect of erbium-doped: yttrium, aluminium and garnet (Er:YAG) laser irradiation on sand-blasted, large grit, acid-etched (SLA) implant surface microstructure according to varying energy levels and application times of the laser. METHODS The implant surface was irradiated by the Er:YAG laser under combined conditions of 100, 140, or 180 ...
متن کاملEffect of Nd:YAG, Ho:YAG, Er:YAG, CO2, and GaAIAs laser irradiation on surface properties of endosseous dental implants.
PURPOSE To analyze potential surface alterations in endosseous dental implants induced by irradiation with common dental lasers. MATERIALS AND METHODS Sandblasted and acid-etched, plasma-sprayed, hydroxyapatite-coated, and smooth titanium discs were irradiated using Nd:YAG, Ho:YAG, Er:YAG, CO2, and GaAIAs lasers at various power settings. The specimens were examined by scanning electron micro...
متن کاملCharacterization and Corrosion Behavior of Hydroxyapatite- Coated Titanium Substrates Prepared Through Laser Induced Liquid Deposition Technique
Titanium and titanium alloys are often used in orthopedic surgery and dentistry because of their especial characteristics such as biocompatibility, mechanical properties, and corrosion resistance. However, their bio- inertness is the most serious drawback for biomedical applications. Therefore, a bioactive coating like hydroxyapatite (HA) is coated on their surface. In this regard, in the prese...
متن کاملEffect of Er:YAG Laser Irradiation on Shear Bond Strength of Two Porcelain Laminate Veneers Bonded to Tooth Surface
Background and Aim: The conventional procedure for removal of porcelain laminate veneers (PLVs) is time-consuming and inconvenient. The purpose of this study was to evaluate the efficacy of Er:YAG laser for debonding of PLVs. Materials and Methods: Forty-eight intact extracted human maxillary anterior teeth received discoid PLVs (24 feldspathic and 24 e-max ceramic). The PLVs had 0.7 mm thickn...
متن کامل